2026 taxable assessment $7,715,900 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $9,714,200; it is not the 2026 billed-year value.
Commercial property report
1 story · 55,510 sqft · CA2 · built 1950
Store · Bt Tremont LP · assessed $7.7M (2026) · 2027 OPA assessment $9.7M. On the 2500 block of Welsh Rd.
“Open” reflects records available then historical records keep their source dates estimates are labeled
Every choice opens the research chat with this property already in context. Curated questions are free.
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:

Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $7,715,900 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $9,714,200; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 8820680002026 taxable assessment equals the full assessed value.
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
built new under a 2024 permit.
View supporting records →Every dated deed, permit, inspection, license, violation, certification, and appeal is placed on the City’s annual assessment line. Select a point to read what happened; the line is an assessment history—not a sale-price chart or appraisal. OPA has also published a 2027 assessment of $9,714,200; it is not yet the billed-year tax basis.
Assessment history · all dated City records marked on the line
Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
This is a store, recorded under the city's commercial category. The homeowner tools (rent estimate, homestead playbook) don't apply, so they're hidden. The full record and owner trail are below.
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Permit PP-2026-006663 · Issued
Install 3 fixtures with pipes
Permit CP-2026-002134 · Issued
FOR LEVEL II ALTERATIONS TO AN EXISTING MERCANTILE TENANT SPACE (RETAIL STORE/SHOPPING CENTER). ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ** NO CERTIFICATE OF OCCUPANCY REQUIRED FOR THIS WORK. ALTERATIONS SHALL BE DONE IN A MANNER THAT DOES NOT IMPACT THE EGRESS OR THE LEVEL OF FIRE PROTECTION PROVIDED AS PER SECTION A-701.1 (EXCEPTION 2) OF THE PHILADELPHIA ADMINISTRATIVE CODE **
Permit GM-2026-002999 · Completed
EZ INTERIOR NON-LOAD-BEARING WALL DEMOLITION - For the interior demolition on NON-Load-Bearing partition walls and ceilings as per attached standard. Deviations from these standards require submission of construction and site plans. Structural alteration or repair is expressly PROHIBITED under this permit. Prohibited structural work includes but not limited to any modification to exterior walls, party wall, floor/roof framing and foundations, including underpinning, excavation and removal of foundation slab. Separate Streets Department permit required for sidewalk and street closures.
Permit ZP-2026-003516 · Issued
Retail Sales - Consumer Goods; Retail Sales - Food, Beverages, and Groceries
Certification BC-2026-004938 · Certified
Expires 2027-02-19
Certification BC-2026-003593 · Certified
Expires 2027-02-09
License 0996588 · Active
Your Neighborhood Grocer, L.L.C. (Grocery outlet of welsh road) · Expires 2027-01-01
License 0977593 · Active
Doner House · Expires 2027-04-29
Permit FP-2025-000518 · Completed
EZ STANDARD KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. INSTALL (1) ONE ANSUL R-102 WET CHEMICAL COMMERCIAL KITCHEN FIRE SUPPRESSION SYSTEM FOR PROTECTION OF KITCHEN EXHAUST HOOD - SEE MECHANICAL PERMIT MP-2024-005444 FOR KITCHEN HOOD.
Certification BC-2025-006016 · Certified
Expires 2026-02-27
Permit ZP-2024-012943 · Issued
One sign as per EZ zoning sign as per picture and standard.
Permit MP-2024-005444 · Completed
FOR THE INSTALLATION OF A TYPE 1 COMMERCIAL KITCHEN HOOD (14'-0") AND ASSOCIATED DUCTWORK, FANS AS PER APPROVED PLANS. SEPARATE PERMITS REQUIRED FOR ELECTRICAL AND FIRE SUPPRESSION WORK. **IMC 2018**
Certification BC-2025-007058 · Certified
Expires 2026-02-03
Permit PP-2024-016139 · Issued
Replacing fixtures in a previously existing restaurant space. This space was a restaurant and we are replacing the existing sinks and not changing or relocating any piping.
Certification BC-2025-003204 · Certified
Expires 2025-12-09
Permit EP-2024-010319 · Completed
Replace lights, switch, receptacles, partial rewire (fishing wire)
Permit CP-2024-004513 · Completed
FOR LEVEL I INTERIOR ALTERATIONS FOR THE USE OF BUSINESS (B) OCCUPANCY AS PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit ZP-2024-007269 · Issued
Eating and Drinking Establishments - Sit-Down Restaurant
Permit CP-2024-003018 · Completed
FOR LEVEL 2 ALTERATIONS FOR FIT-OUT FOR BANK IN SPACE 1. FOR USE AS PREVIOUSLY APPROVED. AS PER APPROVED PLANS.
Certification BC-2024-016919 · Certified
Expires 2025-04-12
Permit EP-2024-003209 · Completed
Provide & install automatic fire alarm system throughout as per NFPA-72 and approved plans .
Certification BC-2024-009267 · Certified
Expires 2025-04-04
Certification BC-2024-011394 · Certified
Expires 2025-03-28
Permit FP-2024-000067 · Completed
TIE INTO EXISTING 4-INCH FIRE SPRINKLER RISER AND EXTEND FIRE SPRINKLER SYSTEM IN ACCORDANCE WITH APPROVED PLANS, HYDRAULIC CALCULATIONS AND NFPA 13.
Permit PP-2023-016110 · Completed
INSTALL 1 LOUNGE SINK, 2 WATER CLOSETS, 2 LAVATORIES, 1 ELECTRIC WATER COOLER, 1 HOT WATER HEATER, 1 MOP SINK AND 3 FLOOR DRAINS ACCORDING TO THE 2018 PPC AND PER PLANS.
Permit GP-2023-008748 · Completed
FOR THE INSTALLATION OF THREE (3) INTERNALLY ILLUMINATED ACCESSORY WALL SIGNS (E03, E04, & E05) AND ONE (1) NON-ILLUMINATED ACCESSORY WALL SIGN (E06). FOR THE REFACING OF ONE (1) EXISTING FREESTANDING SIGN. ALL WORK TO BE DONE PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR ELECTRICAL WORK. SEE ZP-2023-009293 FOR ZONING APPROVAL.
Permit EP-2023-009810 · Completed
Installation of 800 AMP service, as per attached drawings Installation of lighting, as per attached drawings Installation of receptacles and power to HVAC equipment, as per attached drawings. Installation of CAT 5 and low voltage cabling for systems, as per attached drawings. Installation as per 2017 NEC.
Permit MP-2023-003444 · Completed
Mechanical / Fuel Gas Permit for combo CP-2023-004190
Permit ZP-2023-009293 · Completed
Four (4) wall signs on Tenant 14 (aka Space 1 or 2500 Welsh) along Tremont Street, Welsh Road, and US Route 1. See attached plans for details.
Permit CP-2023-004190 · Completed
FOR LEVEL 2 ALTERATIONS FOR FIT-OUT FOR BANK AS PER PLANS. AMENDMENT (12/20/2023) TO ADD A CONFERENCE ROOM AND OTHER MINOR CHANGES PER REVISED PLANS.
Permit CP-2023-002781 · Issued
INTERIOR AND EXTERIOR ALTERATION TO THE REAR PART OF AN EXISTING STRUCTURE. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Case CF-2023-082079 · PASSED
The cited inspection visit was marked passed.
Permit ZP-2023-007857 · Issued
For the partial demolition of the existing structure. Size and locations per plans.
Case CF-2023-082079 · Violation VI-2023-060585 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case CF-2023-082079 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit ZP-2023-006460 · Issued
Financial Services
License 888070 · Inactive
Great Bargain Supermarket LLC · Expires 2023-02-21 · Inactive 2023-04-22
Permit GP-2021-011814 · Completed
For the installation of six (6) statically illuminated wall signs per approved plan.
Permit EP-2021-013847 · Completed
Full electrical wiring of a grocery store including: 229 Lights 1 lighting control panel 10 switches 54 Receptacles 5 Power poles 9 GFCI's 4 Sub-panels As per 2017 NEC
Permit GP-2021-012240 · Completed
FOR THE PARTIAL REFACING OF AN EXISTING FREESTANDING SIGN, AND ERECTION OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS, BELOW THE ROOF LINE OF THE EXISTING DETACHED STRUCTURE AS PER APPROVED PLANS.
Permit PP-2021-022227 · Completed
Installation of rough and finish plumber per plans provided for 10 floor sinks, 3 toilets, 1 urinal, 2 lav sinks, 2 mop sinks, 1 kitchen sink, 1 hot water heater, 2 trench drains
Permit FP-2021-003349 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate (26) sprinkler heads as per NFPA 13 (CP-2021-005393)
Permit MP-2021-007843 · Completed
FOR MECHANICAL ALTERATIONS TO GROCERY STORE TO INCLUDE THE INSTALLATION OF AC UNITS, CONDENSING UNITS, DUCTLESS SPLIT HEAT PUMPS, REGISTERS/DIFFUSERS AND ADDOCIATED DUCTWORK, AS PER APPROVED PLANS.
Permit CP-2021-005393 · Completed
FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS A MERCANTILE OCCUPANCY (RETAIL SALE OF FOOD, BEVERAGES, AND GROCERIES). ALTERATIONS TO INCLUDE THE ERECTION OF PARITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. BUILDING IS FULLY SPRINKLERED IN ACCORDANCE WITH NFPA 13. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK.
Permit ZP-2021-015050 · Issued
Retail Sales - Food, Beverages, and Groceries
Permit ZP-2021-010590 · Issued
FOR THE PARTIAL REFACING OF AN EXISTING FREESTANDING SIGN, AND ERECTION OF TWO (2) STATICALLY ILLUMINATED WALL SIGNS, BELOW THE ROOF LINE OF THE EXISTING DETACHED STRUCTURE. SIZES AND LOCATIONS AS SHOWN IN THE APPLICATION/PLANS. NO CHANGE IN HEIGHT OF EXISTING STRUCTURE.
Permit SP-2021-000602 · Completed
Installation of 12" sewer with trench drain & 6" water main
Permit PP-2021-017096 · Completed
Plumbing Permit for combo SP-2021-000602
Permit GP-2021-008555 · Completed
For the erection of 2 double faced freestanding signs accessory to the existing shopping center as per approved plans.
Permit ZP-2021-004972 · Completed
No Change in Height/area of structure.
Permit EP-2021-004453 · Completed
Removal of existing service. Replacing with new 1200 amp 3 phase 208v service. Also (1) 200 amp "house" panel for landlord. All electrical demolition of existing wiring/devices. All new feeders and disconnects for roof top mechanical units. Temporary lighting and power. All work per 2017 NEC. New addressable fire alarm system per 2016 NFPA 72.
Permit FP-2021-001176 · Completed
FOR THE INSTALLATION OF A SIX (6) INCH FIRE SERVICE LINE WITH BACKFLOW PREVENTOR FOR THE INSTALLATION OF A FIRE SUPPRESSION SYSTEM AS PER NFPA 13 AS PER APPROVED PLANS AND CALCULATIONS.
Permit PP-2021-007039 · Completed
Installation of 4 roof drains. Installation of 4 overflow drains & piping to exterior. Cut and cap gas, water & drains to create a shell tenant space according to the 2018 PPC.
Permit EP-2021-004568 · Completed
Furnish & Install (40) Category 6, Plenum Cables for Voice & Data AS PER NEC 2017
Permit EP-2021-003688 · Completed
INSTALL NEW FIRE ALARM SYSTEM TO COMPLY WITH CITY OF PHILADELPHIA FIRE CODE AND 2016 NFPA 72
Permit EP-2021-003165 · Completed
Alterations to existing tenant space to include new 300a service includes new ct cabinet and disconnect, 80kw generator and transfer switch, sub-panels, demo of (2) existing service 200a services includes saw cutting to expose conduit for peco (107) lights, (39) switches, (75) receptacles, power to (2) rtu and interior hvac equipment. improvements as shown per plans as per 2017 nec. NOTED for maintenance recept. 210.63 '17 NEC.
Permit PP-2021-005811 · Completed
Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.
Permit MP-2021-002134 · Completed
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND APPLIANCES WITH ASSOCIATED DUCTOWORK FOR A MERCANTILE OCCUPANCY. APPLIANCES TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit CP-2021-000238 · Completed
For a new sprinkler room addition at the rear and level III alteration throughout the existing shopping center to create a shell tenant space as per approved plans. Building to be fully sprinklered. Separate permits required for the tenant fit-out and M.E.P.S work.
Permit CP-2021-000882 · Completed
FOR LEVEL II ALTERATIONS TO AN EXISTING TENANT SPACE FOR USE AS MERCANTILE OCCUPANCY (MEDICAL MARIJUANA DISPENSARY), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS, STRUCTURAL IMPROVEMENTS AND ACCESSIBLE IMPROVEMENTS AS SHOWN PER PLANS. TENANT SPACE IS NOT SPRINKLERED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit ZP-2020-009975 · Completed
FOR THE ERECTION OF ADDITIONS TO EXISTING BUILDING (SIZE AND LOCATION AS SHOWN ON PLANS)
Permit ZP-2020-009846 · Issued
Retail Sales - Consumer Goods - Medical Marijuana Dispensary
Permit ZP-2020-007626 · Issued
Retail Sales - Consumer Goods - Medical Marijuana Dispensary
Permit 1021232 · COMPLETED
TO GROUND 1-TEMPORARY 22AMP GENERATOR FOR 1-GFCI OUTLET FOR A CASH REGISTER AND 10 SETS OF STRING LIGHTS ONLY IN A PARKING LOT AS PER 2017 NEC (EAST DISTRICT)
Permit 26579 · COMPLETED
ERECT A 20X40 TENT WITHIN AN ARE APPOX 70X100 DEFINED WITH TEMPORARY FENCING FRONTING WELSH RD APPOX 150 FT FROM ROOSEVELT BLVD FOR THE SALE OF SEASONAL PRODUCE
Case 168998 · PASSED
The cited inspection visit was marked passed.
Permit 874803 · COMPLETED
FOR A MEDICAL MARIJUANA DISPENSARY IN SPACE # 2502-06 AS PART OF AN EXISTING SHOPPING CENTER WITH ALL OTHER USES AS PREVIOUSLY APPROVED IN AN EXISTING STRUCTURE. NO SIGN ON THIS PERMIT.
Permit 827340 · COMPLETED
FOR LEVEL II ALTERATIONS TO AN EXISTING FINANCIAL INSTITUION, WORK TO INCLUDE ACCESSIBILITY IMPROVEMENTS AS SHOWN PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS REQUIRED FOR ALL OTHER WORK.
Permit 783963 · COMPLETED
REPLACEMENT OF ONE CHANNEL LETTER SIGN.
License 596906 · Active
LAS MARGARITAS INC
License 565846 · Active
SALADS NE1 INC (SALADWORKS)
License 561500 · Inactive
SIX S BOYS INC (RETRO FITNESS) · Expires 2014-04-30
Appeal 17510 · CLOSED · Granted
Related permit 385908 · CERTIFICATE FOR PREPARATION AND SERVING OF FOOD FOR TAKE OUT AS PART OF AN EXISTING FITNESS CENTER TO INCLUDE TANNING SALON, PHYSICAL THERAPY AND ACCESSORY RETAIL SALE OF FITNESS EQUIPMENT AND APPAREL AND MASSAGE IN SPACE 2524-30 AS PART OF
Permit 397677 · COMPLETED
REPLACEMENT OF 50' OF CAST IRON MAIN DRAIN 4", FROM BUILDING TO CLEAN-OUT. INSTALL NEW 4" CLEAN OUT TO GRADE IN REAR PARKING LOT
Permit 377279 · COMPLETED
DEMOLITION AND INSTALLATION OF DUCTWORK
License 551486 · Active
SIX S BOYS INC (RETRO FITNESS)
Permit 377470 · COMPLETED
REPLACE 50 EXISTING LIGHT FIXTURES WITH NEW**NO SWITCHING** INSTALL 5 POWER OUTLETS UTILIZE EXISTING ELECTRICAL SERVIUCE AS IS.**NO TELE/DATA AND NOT INSTALLING FIRE ALARM**(EAST DIST)(FITNESS CENTER)
Permit 375849 · COMPLETED
INTERIOR DEMO AND RENOVATIONS, UPGRADES TO FINISHES FOR EXISTING FITNESS CENTER SPACE, NEW PARTITIONS AND FIRE RATED BARRIER/ SEPARATED IN 2 DISTINCTY FIRE AREAS,REPLACE LIGHTING, TILING, CARPETING. NO CHANGE IN USE OR OCCUPANCY CLASSIFICATION. ADD'L PERMITS REQ: ELECTRICAL, PLUMBING, HVAC. PRIOR CO ON RECORD UNDER AP152476
Permit 334924 · COMPLETED
INSTALLATION OF 4 SIGNS FOR RESTAURANT NAME CHANGE.
Permit 330472 · COMPLETED
REMOVE EXISTING SIGNS AND REPLACE WITH SIGNS IN SAME GENERAL LOCATION AS SIGNS PREVIOUSLY APPROVED BY THE ZONING BOARD OF ADJUSTMENT - ACCESSORY TO AN EXISTING RESTAURANT - ROOF SIGN TO BE REMOVED.
Permit 325320 · COMPLETED
REPAIR BRICK OVEN AS PER UL SPECIFICATIONS.
Permit 327630 · COMPLETED
REPLACING EXTERIOR LIGHTING AND SOFFITT AS WELL AS REPLACING WITH NEW ,NO LOAD CHANGE,WE ARE FEEDING NEW SIGN WITH EXISTING FEEDS,22 LIGHTS,2 SIGN TEMP TRAILER AS PER 2008 NEC
Permit 319184 · COMPLETED
IMPROVEMENTS TO EXISTING RESTAURANT EXTERIOR FACADE NEW SIGNS NOT APPROVED IN THIS PERMIT.
Permit 313294 · EXPIRED
RE PIPE AND ADD TANK TO EXISTING ANSUL SYSTEM FOR RESTAURANT (ANSUL R- 102, WET CHEMICAL).
License 517250 · Active
JA JA RESTAURANT INC
Case 146476 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
Case 146476 · CLOSED
City marked the record closed; open the case for the closing reason.
Case 139990 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
Permit 214566 · COMPLETED
REPLACING (11) WATER BOXES AND (12) P.R. VENT BOXES. INSTALLING (1) 5" TYLER TEE (CAST IRON) IN 5" MAIN DRAIN IN PARKING LOT AREA WITH CLEAN OUT TO GRADE.
Case 163151 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
Case 139990 · FAILED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 146476 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 194018 · COMPLETED
ERECT A FLAT WALL SIGN AS PER PLANS.
Permit 202396 · COMPLETED
FOR THE ERECTION OF A SINGLE FACED FLAT WALL SIGN ( 18" X 13'-2"), SIZE AND LOCATION AS SHOWN IN APPLICATION.SIGN ACCESSORY TO A WEIGHT LOSS CENTER WITH COUNCILING AND RETAIL SALES OF PRE-PACKAGED FOODS IN SPACE # (8) WITHIN AN EXISTING SHOPPING CENTER WITH USES AS PREVIOUSLY APPROVED AND EXISTING ACCESSORY PARKING.
Permit 196924 · COMPLETED
INSTALL WET CHEMICAL KITCHEN FIRE SUPPRESSION SYSTEM FOR RESTAURANT IN EXISTING KITCHEN.
Permit 198013 · COMPLETED
REPLACEMENT OF EQUIPMENT AND WIRING UP TO 2005 NEC (EAST DIST)
Permit 177680 · COMPLETED
WIRE ALL OUTLETS, SWITCHES, COOLERS, EQUIPMENT AND EXITS, EMERGENCY AS PER 2005 NEC (EAST DISTRICT)
Permit 144922 · COMPLETED
INSTALL HOOD ASSEMBLY (3)
Permit 186601 · COMPLETED
ADDING THE RETAIL SALE OF PREPACKAGED FOODS INSIDE GYM
License 460292 · Inactive
DAN KRAFT (ZADDOX LLC DBA/RETRO FITNESS) · Expires 2009-04-30 · Inactive 2012-01-31
Permit 185602 · COMPLETED
Case 163151 · FAILED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
License 459357 · Inactive
SALADS NE1 INC (SALADWORKS) · Expires 2026-04-30 · Inactive 2026-06-29
Case 175894 · PASSED
The cited inspection visit was marked passed.
Permit 153888 · COMPLETED
MANUFACTURE AND INSTALL(2) SIGNS AS PER PLANS SUPPLIED PLANS
Permit 173201 · COMPLETED
INSTALLATION OF SIGNAGE ACC TO RESTAURANT
Permit 175287 · COMPLETED
INSTALL FIRE ALARM SYSTEM THROUGH THE FITNESS CENTER ONLY AS PER NFPA72 , HORN/STROBES, SMOKE DETECTORS, PULL STATIONS AND MAIN PANEL (NORTH DISTRICT)
Case 163151 · CLOSED
City marked the record closed; open the case for the closing reason.
Case 175894 · Violation 1073784 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 146709 · Violation 1073793 · CLOSEDCASE
City marked the case closed; that does not mean the original condition never existed.
Case 175894 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 146709 · COMPLETED
TENANT FIT-OUT FOR TAKE-OUT RESTAURANT W/SEATING AS PART OF AN EXISTING AREA SHOPPING CENTER
Permit 156825 · COMPLETED
HVAC DUCTWORK
Permit 170741 · COMPLETED
ERECTION OF TWO (2) NEW ACCESSORY SIGNS.
Permit 171417 · COMPLETED
MOVE RWC
Permit 168709 · COMPLETED
AMEND BUILDING PERMIT #146583 PLAN, REASONS FOR AMENDMENT UNDER GROUND PUBLIC UTILITY LINES BELOW GRADE, CHANGE TO 8" CONCRETE AS PER PLANS
Permit 166330 · COMPLETED
TEMP C.O. FOR PRESALES OFFICE WITHIN THE LOBBY AREA OF THE MAIN ENTRANCEWAY IN SPACE #2524-30 (FITNESS CENTER). SEE ATTACHED PLANS FOR LOCATION.
Permit 168861 · COMPLETED
NEW DUCTWORK & NEW AC UNITS TO EXISTING DUCTWORK PER PLANS
Permit 163616 · COMPLETED
REUSE OF EXISTING ELE SVE, INSTALL 71 RECEPTS, 17 SWIT, 158 LIGHT FIXS, 2 CEIL FANS, 2 TANNING BEDS, 1 HOT WATER HEATER, 3 BAR EQUIP CONNECTS, 15TV OUTLETS, 12 COMMUNICATION OUTLETS, 1 SURROUND SOUND SYSTEM, 3 SPEAKER LOOPS, 9 CAMERAS AS PER 2005 NEC (EAST DIST)
Permit 170716 · COMPLETED
INSTALL HOUSE DRAIN,STACK AND FIXTURES
Permit 163170 · COMPLETED
INSTALLATION OF NEW ROOF TOP UNITS, MECHANICAL PIPING AND ACCESORIES, STRUCTURAL REINFORCING OF FRAMING MEMBERS FOR NEW LOADING CONDITIONS, AS PER PLANS.
Permit 161700 · COMPLETED
NONCOMBUSTIBLE PARTITION WALLS WITH 2 DOORS. ALL NON BEARING PER SUBMITTED PLANS. LICENSED CONTRACTOR REQUIRED.
Permit 153882 · COMPLETED
MANUFACTURE AND(2) INSTALL SIGNS AS PER SUPPLIED PLANS
Permit 163168 · COMPLETED
INSTALLATION OF (5) WATER CLOSETS, (5) LAVATORIES, (1) URINAL, (6) STALL SHOWERS, (1) MOP RECEPTOR, (1) WATER COOLER, (3) FLOOR DRAINS, (2) SINKS, AND (1) FLOOR SINK
Case 146866 · CLOSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. City marked the record closed; open the case for the closing reason.
Case 146866 · FAILED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 158484 · COMPLETED
INSTALL NEW 400AMP 3 PHASE 42 CIRCUIT PANEL, TIE INTO EXISTING 400AMP SAFETY SWITCH, WIRE 15 TON 100AMP 3 PHASE AC UNIT, 10 TON 50 AMP 3 PHASE AC UNIT, - AS PER 2005 NEC (EAST DISTRICT)
Permit 152476 · COMPLETED
TENANT FIT OUT OF LEASED SPACE #2524-30 (FITNESS CENTER) AS PER PLANS. SEPARATE PERMITS REQUIRED FOR MECHANICAL, ELECTRICAL AND PLUMBING.
Case 163151 · Violation 1142340 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 99798 · Violation 967208 · ERROR
Permit 143319 · COMPLETED
LAWFUL OCCUPANCY SIGN
Permit 146583 · COMPLETED
PROPOSED EXTERIOR REFR. WALK IN BOXES. LOCATED AT THE REAR PORTION OF THE BLDG.
Permit 149352 · COMPLETED
Permit 139040 · COMPLETED
UPGRAD EXISTING 200AMP 3 PHASE SERVICE TO 400AMP 3 PHASE FOR FUTURE TENANT AS PER 2005 NEC (EAST DISTRICT)
Case 146866 · PASSED
The cited inspection visit was marked passed.
Permit 139039 · COMPLETED
WIRE NEW HANDICAP RESTROOM WITH 1 LIGHT FIXTURES, 1 FAN, 1 SINGLE POLE SWITCH, INSTALL 2 FIXTURES IN REAR STORAGE ROOM, 3 EXIT/EMER LIGHT UNITS AS PER 2005 NEC (EAST DISTRICT)
Permit 129181 · COMPLETED
MVS DEMO CARPET CEILING, SOME PARTITIONWALLS, VCT, INSTALL TWO (2) NEW PARTITIONS WALLS FOR ADA BATHROOM, GRAB BARS PAPAER DISPENSERS, PRIME WALLS, INSTALL VCT & SUSPENDED CEILING APPROX. 300 SQ. F. EACH
Case 146476 · Violation 1507658 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 146476 · Violation 1507657 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Permit 135920 · COMPLETED
USE CHANGE SHOPPING CENTER TO A RETAIL STORE WITH THE SALE OF CELL PHONES, RELATED WIRELESS EQUIPMENT, ACCESSORIES, WIRELESS SERVICE, AS PART OF EXISTING SHOPPING CENTER
Permit 135694 · COMPLETED
INSTALL NEW 1/2" COPPER WASTE FOR WALL HUNG SINK. INSTALL NEW ADA SINK COMPLETE & ADA TOILET COMPLETE. INSTALL 3/4" BACKFLOW PREVENTOR.
Permit 135349 · COMPLETED
INSTALL 2" WATER DIST PIPE
Permit 120135 · COMPLETED
REGISTER USE OF A FITNESS CENTER WITH MASSAGE (NOT AS DEFINED IN 14-1605)
Appeal 4585 · OPEN · Granted with conditions
Related permit 120135 · PERMIT FOR AN ACCESSORY MASSAGE "NOT PRESCRIBED BY A DOCTOR AND NOT PERFORMED BY A LICENSED PHYSICAL THERAPIST (NO ITEMS AS DEFINED IN SECTION 14-1605 OF PHILADELPHIA ZONING CODE), AS PART OF PROPOSED FITNESS CENTER TO INCLUDE TANNING SALON
Permit 133127 · COMPLETED
REPLACE STORE FRONT AS PER PLAN.
Permit 132564 · COMPLETED
CUSTOMER IS ADDING 1 LIGHT AND SW (20A CIR.) ADDING 1 NEW TANNING BED -( 3 PHASE 12 KW), RELOCATING 1 TANNING BED (3 PHASE 10 KW) (EAST DIST)
Case 146866 · Violation 1009163 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 139990 · CLOSED
City marked the record closed; open the case for the closing reason.
Permit 131106 · COMPLETED
WIRE EXISTING 60AMP 3 PHASE ROOFTOP AC UNIT TIE INTO 200AMP MAIN PANEL,INSTALL NEW 200AMP 3 PHASE SERVICE WITH APPROVED GROUNDING AS PER 2005 NEC (EAST DISTRICT)
Permit 123772 · COMPLETED
REPLACE EXISTING EXIT SIGNS AND EM UNITS, EXIT SIGNS - 10 WITH EM HEAD AND 2 EXIT SIGNS, TOTAL OF 12 , 2 EM UNITS (EAST DIST)
Case 139990 · Violation 1282363 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 139990 · Violation 1282367 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 139990 · Violation 1282366 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 139990 · Violation 1282365 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 139990 · Violation 1282364 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
License 420322 · Inactive
JENNY CRAIG OPERATIONS INC (JENNY CRAIG WEIGHT LOSS CENTER) · Expires 2015-04-30 · Inactive 2015-06-29
Permit 85750 · COMPLETED
ERECT A (1) STORY STRUCTURE "WALK-IN COOLER ACCESSORY TO AN EXISTING RESTAURANT.
Permit 99798 · EXPIRED
ONE SET ILLUMINATED LETTERS ON RACEWAY 18"X13'2".
Permit 99133 · COMPLETED
INSTALL 1 SET ILLUM. LETTERS ON RACEWAY
Permit 97491 · COMPLETED
HVAC INCLUDING DUCTWORK AS PER PLAN
Permit 97799 · COMPLETED
28 RECEPTACLES, 12 SWITCHES, 5 LIGHTS, RELOCATE 10 OLD LIGHTS. (EAST DIST)
Permit 77319 · COMPLETED
SPACE #2510 - EAT-IN/TAKE-OUT RESTAURANT (MORE THAN 30 SEATS;
Appeal 2185 · OPEN · Granted with conditions
CERTIFICATE FOR A TAKE-OUT RESTAURANT WITH SEATING, NO MUSIC, NO LIVE ENTERTAINMENT IN STORE #2510, AS PART OF AN EXISTING AREA SHOPPING CENTER WITH USES AS PREVIOUSLY APPROVED.
Permit 85475 · COMPLETED
FIT-OUT OF A RETAIL SPACE.
Permit 85887 · COMPLETED
REMOVE: ELECTRIC IN WALLS TO BE REMOVED. STRIP STORE ADD 4 OUTLETS TO NEW PARTITIONS, REPLACE EXIT LIGHTING.(EAST DIST)
Permit 85898 · COMPLETED
RELOCATE EXISTING LIGHTING AND OUTLETS (STRIP STORE), DEMO PARTITIONS BEING REMOVED, REPLACE EXIT LIGHTING. (EAST DIST)
Case 117553 · PASSED
The cited inspection visit was marked passed.
Permit 81379 · COMPLETED
TENANT FIT-OUT FOR JENNY CRAG INC. AS PER PLANS. ZONING PERMIT#81374
Permit 82246 · COMPLETED
DEMO OF INTERIOR PARTITIONS. CONSTRUCTION OF NEW FIRE WALL. MODIFY STORE FRONT
Case 117553 · Violation 603141 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 117553 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 81374 · COMPLETED
WEIGHT LOSS CONSULTATION CENTER WITH RETAIL SALES OF PACKAGED FOOD
License 393411 · Active
JAKO ENTERPRISES LTD (KICKS USA)
Case 71913 · PASSED
The cited inspection visit was marked passed.
Case 71913 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 61771 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Case 59176 · CLOSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.
Case 61710 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Case 61771 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 59176 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
License 350180 · Inactive
JA JA RESTAURANT INC · Expires 2016-04-30 · Inactive 2016-06-29
License 310973 · Inactive
ODYSSEY FOODS OF 983 LLC · Expires 2006-04-30 · Inactive 2012-12-22
License 285555 · Inactive
PHILADELPHIA BEAUTY SUPPLY · Expires 2009-06-30
License 201116 · Inactive
PHILADELPHIA BEAUTY SUPPLY · Expires 2006-04-30 · Inactive 2012-01-31
License 209130 · Inactive
ITALIAN BISTRO OF NORTHEAST INC · Expires 2016-04-30 · Inactive 2016-06-29
License 282242 · Inactive
CITIZENS BANK OF PENNSYLVANIA · Expires 2011-07-31
License 281722 · Inactive
THE ATHLETE'S FOOT #63 · Expires 2010-07-31
License 279506 · Inactive
ITALIAN BISTRO OF NORTHEST INC · Expires 2010-07-31
What this record suggests
The City file documents 117 permits touching kitchen work, bathroom work, electrical work, plumbing. 115 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Bt Tremont LP · corporate / LLC owner
• Tax bills mail to 200 Witmer Rd, Horsham PA, 19044 — outside Philadelphia
2500-30 Welsh Rd sits on the 2500 block of Welsh Rd. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 2550 Welsh Rd · 2503 Welsh Rd
This report was assembled Jul 10, 2026, 11:25 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)