2026 taxable assessment $2,100,000 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $20,277,800; it is not the 2026 billed-year value.
Apartment building report
7 stories · 74,662 sqft · CMX3 · built 2024
Apartments · 84 units · Gy Poplar C Development L P · assessed $21M (2026) · 2027 OPA assessment $20M. On the 900 block of N Delaware Ave.

Open the research chat with this property already in context. Curated questions are free.
“Open” reflects records available then historical records keep their source dates estimates are labeled
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:
Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $2,100,000 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $20,277,800; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 8810001042026 OPA taxes $2,100,000 of $21,000,000 assessed. The assessment fields alone do not identify a program, approval date, expiration, or buyer eligibility.
See the assessment math →Applying the same rate to the billed-year full assessment. OPA's numeric split does not say when or whether the current treatment changes.
See the assessment math →This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
new construction appears in a 2024 permit with a reduced taxable assessment shown.
View supporting records →Every dated deed, permit, inspection, license, violation, certification, and appeal is placed on the City’s annual assessment line. Select a point to read what happened; the line is an assessment history—not a sale-price chart or appraisal. OPA has also published a 2027 assessment of $20,277,800; it is not yet the billed-year tax basis.
Assessment history · all dated City records marked on the line
Scroll horizontally to move through the years. Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
This is a apartments, recorded under the city's apartments category. The homeowner tools (rent estimate, homestead playbook) don't apply, so they're hidden. The full record and owner trail are below.
1 open violation
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Case CF-2026-072999 · Violation VI-2026-045293 · OPEN
Case CF-2026-072999 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Certification BC-2026-017874 · Certified
Expires 2027-06-18
Permit FP-2026-001132 · Issued
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the relocation of sprinkler heads as per attached standards. Deviations from these standards require submission of construction and site plans. RELOCATE 35 SPRINKLER HEADS IN CAFE OLE
Permit PP-2026-005006 · Issued
installation of plumbing system for 1-3 comp sink 1 grease trap 2 water heaters 3 toilets 3 lav sinks 2hand sinks 1 floor drain 2 floor sinks 1 comm dishwasher
Certification BC-2026-012844 · Deficient
Case CF-2026-034381 · Violation VI-2026-020825 · SVN ISSUED
Case CF-2026-034381
Permit EP-2026-002192 · Issued
Install Receptacles • Provide and install general-use receptacles as required by NEC code and reduced per plan. • Provide wiring, boxes, devices, supports, and terminations. B. Appliances (Provided by Others) • Provide dedicated circuit / breaker / branch line for each appliance provided by others. • Make all necessary electrical connections including whips, terminations, and final testing (as applicable). • Coordinate exact requirements based on appliance cut sheets/nameplates. C. Service Panels / Distribution • Relocate existing 400A panel to new location as per plan, including: • Disconnect/reconnect feeders as required • Conduit/wiring modifications, extensions, supports • Circuit identification, labeling, and testing • Feeder, breaker, grounding/bonding, panel schedule labeling D. Island Power • Install conduits under slab to provide power as per plan for island receptacles. • Trenching/coring/cutting by others (electrical contractor to provide/route conduit and pull conductors after pathway is ready). • Provide all conductors, terminations, boxes, and device connections for island receptacles. E. HVAC Electrical Connections • Provide electrical connections for existing HVAC units per specifications, including: • Disconnects (if required by code/spec) • Whips/conduit, conductors, terminations • Start-up verification (electrical only) F. Emergency Lighting / Egress • Provide and install all emergency lighting and exit signs as per plan, including mounting, wiring, testing, and labeling. G. Lighting – Fixtures Provided by Others • Run wiring and install lighting circuits and controls to feed fixtures provided by others. Rough/adjust entire fire alarm system Trim out fire alarm system
Certification BC-2026-007197 · Certified
Expires 2027-02-24
Certification BC-2026-006062 · Certified
Expires 2027-02-18
Permit FP-2025-002248 · Issued
EZ KITCHEN FIRE SUPPRESSION- For the installation of New Wet Chemical Kitchen Fire Suppression System as per attached standard. Deviations from these standards require submission of construction and site plans. To install a wet chemical fire suppression system for 16'+4' hoods system.
Permit MP-2025-004651 · Issued
FOR THE INSTALLATION OF ONE (1) 16'-0" AND ONE (1) 4'-0" TYPE I HOOD WITH EXHAUST FAN AND A MAKE UP AIR FAN WITH ASSOCIATED DUCTWORK. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN PROFESSIONAL PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit CP-2025-002900 · Issued
FIT-OUT OF SHELL SPACE ON THE GROUND FLOOR OF A NEW CONSTRUCTION BUILDING (SEE PERMIT CP-2020-005713) FOR A RESTAURANT AS PER APPROVED PLANS. DRY FLOODPROOFING TO BE MAINTAINED. EXISTING BUILDING FULLY SPRINKLERED. *2018 IBC REVIEW* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK**
Certification BC-2025-020259 · Certified
Expires 2026-07-01
Certification BC-2025-012686 · Deficient
Permit ZP-2025-001897 · Issued
Eating and Drinking Establishments - Take-Out Restaurant
Certification BC-2025-017943 · Certified
Expires 2026-02-23
License 949323 · Active
GY Poplar C Development, LP · Expires 2027-04-16
Permit ZP-2023-010528 · Issued
Residential - Household Living - Multi-Family; Visitor Accommodations
Case CF-2023-022851 · PASSED
The cited inspection visit was marked passed.
Appeal HA-2023-001986 · Closed · Complete
See Attached
Case CF-2023-022851 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit EP-2023-002810 · Completed
INSTALL MAIN SERVICE, INSTALL SERVICE EQUIPMENTS AND ALL METERS( 84 UNITS, COMMERCIAL SPACE AND HOUSE METER), WIRING THROUGHOUT, INSTALL OUTLETS, SWITCHES, LIGHT FIXTURES, SMOKE DETECTORS,SMOKE DETECTION&DOOR RELEASES IN HORIZONTAL EXITS, EMERGENCY LIGHTS, EXIT SIGN , GROUNDING AND FIRE ALARM SYSTEM ,RESCUE ASSISTANCE SYSTEM, ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS 2017 NEC CODE , 2016 NFPA-72, 2018 PHILA FIRE CODE.
Permit FP-2022-003119 · Completed
INSTALL ONE (1) NEW FIRE SUPPRESSION SYSTEM TO INCLUDE A 4" FIRE SERVICE IN ACCORDANCE WITH NFPA 13 THROUGHOUT THE BUILDING. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS. ALL WORK SHALL BE PERFORMED BY A FIRE SUPPRESSION CONTRACTOR LICENSED BY THE CITY OF PHILADELPHIA.
Permit PP-2022-016069 · Completed
INSTALL 108 SHOWER/TUBS, 120 WATER CLOSETS, 120 LAVATORIES, 84 KITCHEN SINKS, 84 WASHING MACHINE BOXES, 6 HOSE BIBBS, 4 ROOF DRAINS, 2 BACKFLOW PREVENTERS, 6 FLOOR DRAUNS, 1 BOOSTER PUMP AND 84 HOT WATER HEATERS ACCORDING TO THE 2018 PPC.
Permit FP-2023-000752 · Completed
Fire Suppression System Permit for combo SP-2023-000211
Permit PP-2023-004216 · Completed
Plumbing Permit for combo SP-2023-000211
Permit SP-2023-000211 · Expired
For sitework to install a new eight (8) inch fire sprinkler service line and a new four (4) inch domestic water service line, along with exterior building drainage for an under-construction detached structure (Building "C"; see CP-2020-005713 for new construction permit), as per plans; see sub-permits for associated fire suppression and plumbing work; no other work on this permit; see ZP-2020-09612 for zoning approval of new construction.
Permit EP-2023-002838 · Expired
ELECTRICAL ROUGH WORK TO INSTALL MAIN SERVICE, INSTALL SERVICE EQUIPMENTS AND ALL METERS( 84 UNITS, COMMERCIAL SPACE AND HOUSE METER), WIRING THROUGHOUT, INSTALL OUTLETS, SWITCHES, LIGHT FIXTURES, SMOKE DETECTORS,SMOKE DETECTION&DOOR RELEASES IN HORIZONTAL EXITS, EMERGENCY LIGHTS, EXIT SIGN , GROUNDING AND FIRE ALARM SYSTEM ,RESCUE ASSISTANCE SYSTEM, ALL WORK TO BE DONE ACCORDING TO APPROVED DRAWINGS 2017 NEC CODE , 2016 NFPA-72, 2018 PHILA FIRE CODE.
Case CF-2023-022851 · Violation VI-2023-017178 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Permit EP-2023-000260 · Cancelled
Rough-In Permit for EP-2023-000171 Install 2400 amp 3 phase service with 84 gang meter packs. Wiring for power and lighting for 84 dwelling units, 2 retail commercial spaces, 2 elevators and parking garage. Install 30kw backup generator. Install light fixtures, switches, receptacles and 120v interconnected co's and smoke detectors. Install low voltage fire alarm system. All work as per drawings and per NEC 2017, NFPA 72 and City of Philadelphia Code requirements.
Permit MP-2022-003760 · Completed
FOR THE INSTALLATION OF AN HVAC MECHANICAL SYSTEM TO INCLUDE ELECTRIC HEATERS, CONDENSING UNITS, AIR HANDLING UNITS, DIFFUSERS/REGISTERS/GRILLES, AND ASSOCIATED DUCTWORK. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S SPECIFICATIONS. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY, CONTACT THE DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS ARE REQUIRED FOR ALL OTHER WORK.
Permit PP-2022-016085 · Expired
Rough-In Permit for PP-2022-016069 Installation of 84 kitchens, 84 laundries, 102 tubs, 117 toilets, 117 lavatories, 84 hot water heaters
Permit EP-2022-002172 · Completed
Install 200amp service for temporary power during construction - stringer lights and GFCI protected outlets. All work as per 2017 NEC and City of Philadelphia code requirements.
Permit ZP-2021-015962 · Issued
Unity of Use
Permit ZP-2021-015959 · Issued
Vacant
Permit CP-2020-005713 · Completed
NEW CONSTRUCTION OF A SEVEN (7) STORY STRUCTURE (BUILDING 'C') TO INCLUDE VACANT COMMERCIAL SPACE (USE REGISTRATION & FIT-OUT PERMITS REQUIRED PRIOR TO OCCUPANCY), EIGHTY FOUR (84) DWELLING UNITS AND ACCESSORY PARKING GARAGE AS PER APPROVED PLANS. BUILDING TO UTILIZE HORIZONTAL SEPARATIONS TO CREATE TWO (2) SEPARATE BUILDINGS WITH TWO (2) DIFFERENT CONSTRUCTION TYPES (1ST & 2ND FLOORS - TYPE IA AND 3RD THROUGH 7TH FLOORS - TYPE IIIA). FIRE RETARDANT TREATED STUDS AND SHEATHING REQUIRED FOR TYPE III CONSTRUCTION. BUILDING LOCATED WITHIN THE ZONE AE SFHA AND TO INCLUDE MANUAL FLOODPROOFING WITH EMERGENCY OPERATIONS PLAN. ELEVATION CERTIFICATE REQUIRED TO BE SUBMITTED TO FIELD INSPECTOR UPON COMPLETION OF FIRST FLOOR. BUILDING TO BE FULLY SPRINKLERED PER NFPA 13 AND INCLUDE STANDPIPES PER NFPA 14. FIRE WATCH REQUIRED PER CODE BULLETIN F-2001. *2018 IBC* **SEPARATE PERMITS REQUIRED FOR MEP & FIRE SUPPRESSION WORK** AMENDMENT APPROVED 6/10/23 AMEND NEW CONSTRUCTION PERMIT CP-2020-005713 TO INCLUDE HORIZONTAL EXIT AND REMOVAL OF EMERGENCY GENERATOR AS PER APPROVED PLANS.
License 516109 · Inactive
RIGHTER PARKING COMPANY · Expires 2011-10-04
License 287536 · Inactive
AZTEC PARKING INC · Expires 2009-06-30
What this record suggests
The City file documents 22 permits touching kitchen work, electrical work, plumbing, roof work. 18 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Gy Poplar C Development L P · corporate / LLC owner
• Holds an active rental license for this address
900 N Delaware Ave sits on the 900 block of N Delaware Ave. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 940 N Delaware Ave · 970 N Delaware Ave
This report was assembled Jul 10, 2026, 10:49 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)