2026 taxable assessment $346,400 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $480,400; it is not the 2026 billed-year value.
House report
2 stories · 2,400 sqft · RSA3 · built 1953
Owner-occupancy signal · assessed $446K (2026) · 2027 OPA assessment $480K. On the 400 block of Hartel Ave.

Open the research chat with this property already in context. Curated questions are free.
“Open” reflects records available then historical records keep their source dates estimates are labeled
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:
Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $346,400 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $480,400; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 6312118002026 OPA removes $100,000 from the taxable assessment through the owner-occupant exemption.
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Wall Covering Replacement permit recorded in 2025.
View supporting records →The record, translated into moves — what a buyer, the owner, and a landlord would each want to check next under Philadelphia's actual rules.
Federal law requires a lead-paint disclosure at sale for any pre-1978 home. If it will be rented, Philadelphia also requires a lead-safe or lead-free certificate before a rental license can issue.
Single-family attached. Converting to a duplex or apartments needs a use variance the zoning board rarely grants — Pennsylvania courts require a physical hardship of the lot itself, and economics alone do not qualify.
Derived from the fetched property records and linked City guidance as of 2026. Assessment treatment is not a substitute for an exemption approval, live balance, title report, license, occupancy certificate, or inspection. Informational only — not legal, tax, or investment advice.
Every fetched annual City assessment for this house, compared with its block and ZIP. The figures show assessment change, the billed-year tax estimate, dated tax records, and recorded transfers. They do not estimate market appreciation or investment return.
Assessment vs. the block and ZIP · every dated City record marked on the line
Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
Wall Covering Replacement permit recorded in 2025.
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Permit GM-2025-005553 · Completed
For minor construction work at the subject property in accordance with all applicable provisions of the Philadelphia Code, all references codes and standards, and the attached EZ Standard, where included. Deviation from this standard shall result in permit revocation. A separate permit from the Philadelphia Department of Streets is required for any sidewalk and street closures. All means of pedestrian protection required at the site in accordance with the Philadelphia Building Code Chapter 33 shall be in place prior to start of work.
Permit EP-2023-005819 · Completed
Run a dedicated line 40 amp 240 volt from the panel to the hot tub up to 85 feet , Run a dedicated line 60 amp 240 volt up to 85 feet from the electric panel to the swim spa Supply and install 60 amp Spa GFCI protected 2 space 4 circuit spa panel on the outside corner Supply and install 40 amp swim spa GFCI protected 2 space 4 circuit spa panel on outside corner of the house , 2 carflex whips from the disconnects to the equipment 120 volt line for the general use AS PER NEC 2017
Permit GP-2023-002482 · Completed
EZ STANDARDS RETAINING WALLS- For New Retaining Walls as per attached standard. Deviations from these standards require submission of construction and site plans. In the rear yard. *Please provide PA One Call and add it to the EZ Retaining wall form*
Permit GM-2023-002478 · Completed
EZ PERMIT STANDARDS POOL AND SPAS- For pools and spas accessory to an Existing One Family Dwellings as per attached standards. Deviations from these standards require submission of construction and site plans. Separate permits are required for all electrical and plumbing installations associated with the installation of the pool or spa. (Homeowner is performing the work)
Permit 838483 · COMPLETED
REPLACE 3/4" K COPPER WATER LINE PA ONE CALL #2017-3411892
Case 436505 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
Permit 607805 · COMPLETED
1-3PC BATHROOM, 1-LAUNDRY TUB & 1-UTILITY SINK (SFD) THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
Permit 597654 · COMPLETED
INSTALL 125AMP SUBPANEL,(5)20AMP CIRCUITS IN STORAGE ROOM,RECEPTS AND LIGHTS AS PER 2008 NEC (EAST DISTRICT)
Permit 576384 · COMPLETED
STRUCTURAL MODIFICATIONS, PARTIAL DEMO AND REBUILDING TO REDUCE FOOTPRINT AND ROOF HEIGHT OF EXISTING, DETACHED, ACCESSORY STORAGE STRUCTURE/SHED, AS PER PLANS. MEAN AVERAGE OF GABLE ROOF SHALL NOT EXCEED 15 FEET FROM AVERAGE GRADE. SEPARATE ELECTRICAL, PLUMBING, AND HVAC PERMITS ARE REQUIRED.
Case 436505 · CLOSED
City marked the record closed; open the case for the closing reason.
Permit 564486 · COMPLETED
STRUCTURAL MODIFICATIONS TO REDUCE FOOTPRINT, AND ROOF HEIGHT OF EXISTING, DETACHED, ACCESSORY STORAGE STRUCTURE/SHED, AS PER PLANS. MEAN AVERAGE OF GABLE ROOF SHALL NOT EXCEED 15 FEET FROM AVERAGE GRADE. SEPARATE BUILDING PERMIT IS REQUIRED.
Case 436505 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Appeal 23400 · CLOSED · Denied
Related permit 544091 · PERMIT FOR THE LEGALIZATION OF AN ALTERATION TO AN EXISTING DETACHED ACCESSORY STRUCTURE TO AN EXISTING DETACHED SINGLE FAMILY DWELLING,(SIZE AND LOCATION TO BE AS SHOWN IN THE APPLICATION)
Case 436505 · Violation 3462476 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 436505 · Violation 3462475 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Permit 246000 · COMPLETED
INSTALL PHOTOVOLTAIC SOLAR ARRAY, ROOF MOUNTED, GRID TIED.SOLAR PANELS AS PART OF A SINGLE FAMILY DWELLING TO BE INSTALLED PER SEALED PLAN
Permit 246022 · COMPLETED
SOLAR PHOTOVOLTAIC SYSTEM, ROOF MOUNTED, GRID-TIED, INSTALLING 4.2 KW ARRAY, DC DISCONNECT, ENPHASE INVERTERS, AC DISCONNECT, RE-ROUTE TO INTERIOR MAIN BREAKER, AS PER 2005 NEC
Permit 168388 · REVOKED
FOR THE ERECTION OF A REAR YARD ADDITION TO BE USED AS A IN-LAW SUITE IN ACCORDANCE WITH THE PHILADELPHIA ZONING CODE. ALL WORK SHALL COMPLY WITH THE APPROVED PLANS.
Permit 62061 · COMPLETED
FOR THE PARTIAL DEMOLITION OF AN EXISTING REAR YARD PORTION OF A RESIDENTIAL STRUCTURE, FOR THE COMPLETE DEMOLITION OF ACCESSORY DETACHED GARAGE. FOR THE ERECTION OF A TWO (2) STORY REAR YARD ADDITION SUPPORTED BY A EXCAVATED FOOTING & FOUNDATION BASEMENT SYSTEM. FOR THE CREATION OF A SIDE YARD PARKING SLOT NOT WITHIN THE REQUIRED SIDE YARD SET BACK. SPACE SHALL BE A MINIMUM OF 8 1/2' X 18'-0". ALL WORK SHALL CONFORM TO THE APPROVED SITE PLANS.
What this record suggests
The City file documents 13 permits touching bathroom work, electrical work, plumbing, roof work. 12 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Flags: 1 zoning/board appeal on record. Informational only — not investment advice or a consumer report (FCRA).
The city assessor's field record — the physical spec sheet behind the assessed number.
OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.
442-44 Hartel Ave sits on the 400 block of Hartel Ave. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 446 Hartel Ave · 436-38 Hartel Ave
This report was assembled Jul 10, 2026, 3:55 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)