2026 taxable assessment $342,600 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $387,700; it is not the 2026 billed-year value.
Mixed-use report
2,454 sqft · CMX1 · built 1915
Investor / LLC · assessed $343K (2026) · 2027 OPA assessment $388K · sold 2×. On the 2100 block of S 10th St.

Open the research chat with this property already in context. Curated questions are free.
“Open” reflects records available then historical records keep their source dates estimates are labeled
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:
Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $342,600 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $387,700; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 8715571002026 taxable assessment equals the full assessed value.
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
built new under a 2020 permit, sold for $550K in 2023.
View supporting records →The record, translated into moves — what a buyer, the owner, and a landlord would each want to check next under Philadelphia's actual rules.
Federal law requires a lead-paint disclosure at sale for any pre-1978 home. If it will be rented, Philadelphia also requires a lead-safe or lead-free certificate before a rental license can issue.
The fetched license records do not show an active Rental License. Ownership type or a tax mailing address does not prove that tenants occupy the property; if it is rented, verify the current license and legal occupancy in eCLIPSE.
Derived from the fetched property records and linked City guidance as of 2026. Assessment treatment is not a substitute for an exemption approval, live balance, title report, license, occupancy certificate, or inspection. Informational only — not legal, tax, or investment advice.
Batp Re Holdings 1 LLC · corporate / LLC owner
• Tax bills mail to 28 Rockhill Rd, Bala Cynwyd PA, 19004 — outside Philadelphia
How this building has moved and where it's pointed: every fetched annual City assessment, charted against its block and ZIP; appreciation includes the full-period compound rate and the latest year-over-year change. The 5-year figure simply extends that historical pace. Yield estimates rent-vs-price from area rents. Ask the record to dig into any number.
Assessment vs. the block and ZIP · every dated City record marked on the line
Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
built new under a 2020 permit, sold for $550K in 2023.
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Certification BC-2026-019171 · Certified
Expires 2027-07-07
Certification BC-2025-017983 · Certified
Expires 2026-07-07
Permit PP-2024-016565 · Completed
Installation of 3/4" backflow
Certification BC-2024-022749 · Certified
Expires 2025-08-12
Permit EP-2024-006690 · Completed
INSTALL LIGHTS NORMAL & EMERGENCY, SWITCHES, SENSORS, & RECEPTACLES. PROVIDE POWER TO THE HVAC EQUIPMENT. ALL WORK IN ACCORDANCE WITH THE 2017 NEC. ** THE 200 AMP SWEVICE & PANEL ARE EXISTING.
Permit MP-2024-002988 · Completed
FOR THE INSTALLATION OF HVAC APPLIANCE, EQUIPMENT, DUCTWORK AND REGISTERS/DIFFUSERS PER APPROVED PLANS AND MANUFACTURER'S SPECIFICATIONS.
Permit CP-2024-002849 · Completed
FOR LEVEL I ALTERATION FOR THE CHANGE OF OCCUPANCY TO BUSINESS (B) OCCUPANCY FROM FIRST THROUGH THIRD FLOORS WITHIN AN EXISTING ATTACHED BUILDING. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Appeal ZP-2023-009742 · Completed · Granted
Related permit ZP-2023-009742 · Permit for a business and professional office in the entire structure.
Permit ZP-2023-009742 · Issued
Office - Business and Professional
Case CF-2020-086180 · PASSED
The cited inspection visit was marked passed.
Permit EP-2023-009210 · Issued
INSTALL NEW 400 AMP SERVICE AND METER-BANK( ON SIDE OF BUILDING). ALL WORK IS TO BE DONE ACCORDING TO APPROVED DRAWINGS-2017 NEC.
Case CF-2020-086180 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
2023
Permit EP-2020-011318 · Completed
REWIRE LIGHT FIXTURES, OUTLETS, SWITCHES, SMOKE DETECTOR AND NEW INSTALLATION OF FIRE ALARM AS PER 2017 NEC AND NFPA 72 ** THE NEW WORK IS ON THE 2ND & 3RD FLOORS.**
Case CF-2020-086180 · Violation VI-2020-051921 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case CF-2020-086180 · Violation VI-2020-051920 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case CF-2020-086180 · Violation VI-2020-051919 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case CF-2020-086180 · Violation VI-2020-051918 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Permit MP-2020-005389 · Completed
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- For the installation of New Ductwork, Registers/Grilles/Diffusers, and Warm-Air Appliances as per attached standards. Deviations from these standards require submission of construction and site plans. *ROOFTOP UNITS NOT ALLOWED ON THIS PERMIT UNLESS ON APPROVED BUILDING PLANS* Install one HVAC system for Second and third floor existing unit Goodman 96% 80000 BTU furnace with 13 seer 3 ton ac Total 9 registers
Permit PP-2020-008909 · Completed
Alterations: Interior plumbing. All proposed work to be done in accordance with Philadelphia Plumbing Code 2018.
Permit EP-2020-007594 · Cancelled
EXISTING 200 AMP SERVICE; RECESSED LIGHTS IN MIDDLE AND BACK BEDROOMS, CEILING FAN IN ALL BEDROOMS AND LIVING ROOM; GFCI SWITCHES IN BATHROOM AND KITCHEN WHERE REQUIRED PER 2017 CODE
Permit CP-2020-000160 · Completed
INTERIOR ALTERATION TO THE EXISTING DWELLING UNITS ON THE SECOND AND THIRD FLOOR AS PER APPROVED PLAN
Permit 1004997 · COMPLETED
EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION, NO UNDERPINNING, EXCAVATION, AND REMOVAL OF FOUNDATION SLAB. NO WORK MAY BE PEFORMED IN THE BASEMENT OR CELLAR)
Case 580591 · PASSED
The cited inspection visit was marked passed.
Case 580591 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 804612 · Issued
INSTALL FIRE ALARM SYSTEM WITH FIRE PANELS, SMOKE DETECTORS, HORNS, STROBES, HORNS/STROBES, PULL STATIONS AND LIGHTS AS PER NFPA 72
Case 580591 · Violation 4774814 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 580591 · Violation 4774815 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 573071 · PASSED
The cited inspection visit was marked passed.
Case 573071 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 573071 · Violation 4227898 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 573071 · Violation 4227897 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 573071 · Violation 4227899 · ERROR
Case 573071 · Violation 4227900 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 83836 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
Permit 175984 · COMPLETED
CURB TRAP, FRESH AIR INLET AND 6" BACKWATER VALVE
Permit 167436 · COMPLETED
CURB TRAP BACK WATER VALVE AND FRESH AIR INLET
Case 85424 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 85424 · CLOSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.
Case 83836 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
License 198548 · Inactive
VILLARI BROS BAKERY · Expires 2018-04-30 · Inactive 2018-06-29
What this record suggests
The City file documents 15 permits touching kitchen work, bathroom work, electrical work, plumbing. 14 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Flags: 1 zoning/board appeal on record. Informational only — not investment advice or a consumer report (FCRA).
The city assessor's field record — the physical spec sheet behind the assessed number.
OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.
What owning 2134 S 10th St takes, at your price and your rate. Taxes start with an annual estimate from the City’s taxable assessment, not a current bill or balance; rent starts at the area median. Assessed value is not an asking price — set the price slider to the real one.
When this house last sold (2023) a 30-year mortgage ran about 6.81% — Freddie Mac's average that year.
Estimates for orientation, not advice. Assumes a 30-year fixed loan, $1,400/yr insurance, 1% of price/yr maintenance; taxes use this parcel's taxable assessment, not a live Tax Center balance.
2134 S 10th St sits on the 2100 block of S 10th St. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 2132 S 10th St · 2136 S 10th St
This report was assembled Jul 10, 2026, 3:49 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)