2026 taxable assessment $0 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $150,264,300; it is not the 2026 billed-year value.
Commercial property report
63,402 sqft · CMX4 · built 1985
Commercial · Whyy INC · fully tax-exempt (2026 OPA). On the 100 block of N Independence Mall.
“Open” reflects records available then historical records keep their source dates estimates are labeled
Every choice opens the research chat with this property already in context. Curated questions are free.
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:

Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $0 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $150,264,300; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 7717386002026 OPA shows a zero or de minimis taxable assessment. The open assessment split does not establish the exemption's legal basis, continuing eligibility, or treatment after a transfer.
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Owner pulled a addition and/or alteration permit in 2026.
View supporting records →Every dated deed, permit, inspection, license, violation, certification, and appeal is placed on the City’s annual assessment line. Select a point to read what happened; the line is an assessment history—not a sale-price chart or appraisal. OPA has also published a 2027 assessment of $150,264,300; it is not yet the billed-year tax basis.
Assessment history · all dated City records marked on the line
Select an icon to see everything recorded near that point.
This is a commercial, recorded under the city's commercial category. The homeowner tools (rent estimate, homestead playbook) don't apply, so they're hidden. The full record and owner trail are below.
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Permit EP-2025-010170 · Completed
REPLACE COLOR KINETICS LIGHTING WITH UPGRADED LIGHTING ON 7TH STREET FACADE PER PLANS
Certification BC-2025-019815 · Certified
Expires 2026-05-15
Permit EP-2025-003649 · Completed
INSTALL FIRE ALARM SYSTEM ACCORDING TO THE 2017 NEC, 2016 NFPA 72 AND PER PLANS.
Permit EP-2025-001482 · Completed
Furnish and install 22 electrical receptacles, 2 dedicated quads, 11 quads, 3 wall furniture feeds, 100 amp panel, wiring for 2 water heaters, 2 dedicated GFI receptacles, 4 GFI's, 2 AC units, 70 lights, 2 exit signs, lighting controls, tele-data and fire alarm as per drawings .
Permit PP-2025-001049 · Completed
• Furnish and install [2] Sinks, [2] Electric Water Heaters, [2] Open Site Drains, [2] Sink Drain Pumps • Provide labor and materials to extend from existing sanitary, vent and domestic water as shown.
Permit MP-2025-000465 · Completed
FOR THE INSTALLATION OF REGISTERS, DIFFUSERS, AND ONE APPLIANCE. APPLIANCE TO BE INSTALLED IN ACCORDANCE WITH THE MANUFACTURER’S SPECIFICATIONS. FOR USE AS PREVIOUSLY APPROVED. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK.
Permit FP-2025-000172 · Completed
EZ PERMIT SPRINKLER RELOCATION (NFPA 13)- For the Relocation of Sprinkler Heads as per attached standards. Deviations from these standards require submission of construction and site plans. Relocate 26 existing sprinkler heads
Permit CP-2024-006382 · Completed
FOR LEVEL II ALTERATIONS TO AN EXISTING BUILDING FOR USE AS A BUSINESS OCCUPANCY (WHYY BROADCAST STUDIO/OFFICES), ALTERATIONS TO INCLUDE THE ERECTION OF PARTITION WALLS, PROVIDE FINISHES/FURNISHINGS AND ACCESSIBILITY IMPROVEMENTS THROUGHOUT. ALL WORK TO BE DONE PER APPROVED PLANS. IF FIELD CONDITIONS VARY CONTACT DESIGN ENGINEER PRIOR TO THE START OF ANY WORK. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. ** NO CERTIFICATE OF OCCUPANCY REQUIRED FOR THIS WORK. ALTERATIONS SHALL BE DONE IN A MANNER THAT DOES NOT IMPACT THE EGRESS OR THE LEVEL OF FIRE PROTECTION PROVIDED AS PER SECTION A-701.1 (EXCEPTION 2) OF THE PHILADELPHIA ADMINISTRATIVE CODE ** **AMENDMENT (3-27-2025) ADDING AN "AKA" ADDRESS TO PERMIT (150 NORTH 6TH ST) AS INCLUDED ON THE APPROVED PLANS. NO OTHER CHANGES WITH THIS AMENDMENT **
Certification BC-2025-003080 · Certified
Expires 2025-09-06
Certification BC-2024-024676 · Certified
Expires 2025-08-30
Certification BC-2023-018261 · Certified
Expires 2024-08-29
Certification BC-2023-018569 · Certified
Expires 2024-08-29
Certification BC-2022-013962 · Certified
Expires 2023-09-26
Certification BC-2021-003801 · Certified
Expires 2022-09-02
Permit MP-2021-002147 · Completed
FOR ALTERATIONS TO AN EXISTING HVAC SYSTEM TO INCLUDE REPLACEMENT OF RTUs, VAV'S, AND ASSOCIATED DUCTWORK AND PIPING. ALL WORK TO BE DONE PER APPROVED PLANS AND IN ACCORDANCE WITH 2018 IMC. SEPARATE PERMITS TO BE OBTAINED FOR ALL OTHER WORK. IF SITE CONDITIONS VARY, CONTACT DESIGN ENGINEER PRIOR TO START OF WORK.
Permit EP-2021-003240 · Completed
Electrical: Install new distribution equipment, lighting, branch wiring, devices, and telecommunications cabling/devices/equipment as per the NEC 2017. Fire Alarm: Install new fire alarm devices and cabling connected to the existing system as in accordance with the 2016 NFPA 72.
Permit EP-2021-004892 · Expired
Remove and replace (8)existing light fixtures as per 2017 nec
Permit 26366 · COMPLETED
06/19/19 ERECT TENT: 20X50
Permit 969871 · COMPLETED
INSTALL 32-PORT DROPS, 1-QUAD PORT, 2-48 PORT CAT6 PATCH PANELS PLENUM TATED CABLE WITH ALL RUNS LESS THAN 300' AS PER NEC 2008
Permit 26137 · COMPLETED
04/01/19 ERECT TENT: 20X20
Permit 949064 · COMPLETED
INSTALL FIRE ALARM USING EXISTING SYSTEM AS PER DRAWINGS TO INCLUDE 19 SPEAKER/STROBES, 4 STOBES, 4HEAT DETECTORS, 1 SMOKE DETECTOR AND 1 PAD PANEL AS PER NFPA 72.(CC DIST)
Permit 943548 · COMPLETED
INSTALL LIGHTING, RECEPTACLES AND HVAC FEEDERS AS PER DRAWINGS USING EXISTING PANEL H4NW 480/277V 225A 3PH AND EXISTING PANEL A4A (SECTION 1) 208/120V 200A 3 PH AND EXISTING PANEL A4A (SECTION2) 208/120V 225A 3PH. TEMP POWER STAND AND TEMP LIGHTS. WE WILL FILE A SEPARATE FIRE ALARM PERMIT AS PER 2008 NEC.
Permit 945693 · COMPLETED
FURNISH AND INSTALL NEW SANITARY, SANITARY VENT AND DOMESTIC WATER PIPE TO NEW BATHROOM. FURNISH AND INSTALL 1 WC, 1 LAV, 2 SH, 2FD AND 2 UNDERMOUNT LAVS. THE INSTALLATION WILL COMPLY WITH THE 2004 PHILA PLUMBING CODE.
Permit 940254 · COMPLETED
NO CHANGE IN USE AND OCCUPANCY CLASSIFICATION. LEVEL II INTERIOR ALTERATIONS AS PER APPROVED PLANS. SEPARATE PERMIT REQUIRED FOR MEP AND FIRE SUPPRESSION WORK *ASBESTOS ABATEMENT REQUIRED PRIOR TO COMMENCEMENT OF WORK*
Permit 25914 · COMPLETED
10/24/18 ERECT TENT 20X50
Permit 909817 · EXPIRED
EZ PERMIT DUCTWORK & WARM-AIR APPLIANCES- FOR THE INSTALLATION OF NEW DUCTWORK, REGISTERS/GRILLES/DIFFUSERS, AND WARM-AIR APPLIANCES AS PER ATTACHED STANDARD. DEVIATIONS FROM THIS STANDARD WILL RESULT IN PERMIT REVOCATION AND REQUIRE SUBMISSION OF CONSTRUCTION PLANS.
Permit 25483 · COMPLETED
ERECTION OF ONE TENT 20' X 50', ASSEMBLED 5/1/18, OCCUPIED 5/3/18, DISASSEMBLED 5/4/18.
Permit 24946 · COMPLETED
6/12/17 ERECT ASSEMBLY TENT 30X105, 20X30, 9X65
Case 543307 · CLOSED
City marked the record closed; open the case for the closing reason.
Case 543307 · Violation 4002207 · ERROR
Case 543307 · Violation 4002208 · ERROR
Case 543307 · FAILED
The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 24169 · COMPLETED
5/2/16 ERECT ASSEMBLY TENT 9X65, 20X30
Permit 688393 · COMPLETED
PROVIDE A TEMPORARY 50KW GENERATOR FOR AN EVENT ON 5/3/16 START AT 3PM TO 9PM THE GENERATOR WILL BE REMOVED ON 5/3/16 AS PER 2008 NEC (CC DISTRICT) GENERATOR MUST BE INSPECTED BY 3RD PARTY AGENCY
Permit 684270 · COMPLETED
INSTALL DRAIN WASTER AND VENT PIPE FOR (1) WATER CLOSET, (1) LAV AND (4) KITCHEN SINKS. THE INSTALLATION WILL COMPY WITH THE PHILADELPHIA PLUMBING CODE 2004
Permit 660119 · COMPLETED
RELOCATE 8 EXISTING DIFFUSERS TO NEW LOCATION WITHIN A FEW FEET
Permit 648603 · COMPLETED
FOR THE RELOCATION OF RECONNECTION OF TEN (10) DIFFUSERS.
Permit 648624 · COMPLETED
INSTALLATION OF WASHING BOX AND UTILITY SINK,INSTALL NEW DRAIN WASTE AND VENT PIPE WITH WATER SUPPLY LINES. THE INSTALLATION WILL COMPLY WITH THE PHILADEPHIA PLUBMING CODE 2004
Permit 639361 · COMPLETED
INSTALL WASTE, VENT, AND WATER SUPPLY PIPING FOR (1) SINK KITCHENETTE THE INSTALLATION WILL COMPLY WITH THE PHILADELPHIA PLUMBING CODE 2004
Permit 639356 · COMPLETED
RELOCATE EXISITING GRILLES AND REGISTERS TO ACCOMODATE NEW ROOM LAYOUT.QTY7
Permit 633966 · EXPIRED
SIDEWALK SHELTER PLATFORM SHED SCAFFOLD
Permit 633120 · COMPLETED
RELOCATE (8) EXISTING REGISTERS TO ACCOMODATE NEW ROOM LAYOUT
Permit 633114 · COMPLETED
RELOCATE (5) EXISTING REGISTERS TO ACCOMDATE NEW ROOM LAYOUT
Permit 633209 · COMPLETED
DEMO 1 SINK AND INSTALL WATER LINE TO BOTTLE FILL STATION.- THE INSTALLATION WILL COMPY WITH THE PHILADEPHIA PLUBMING CODE 2004
Permit 629628 · COMPLETED
INSTALLATION OF DRAIN PIPING AND DOMESTIC WATER PIPING FOR ONE (1) KITCHENETTE SINK.- THE INSTALLATION WILL COMPY WITH THE PHILADEPHIA PLUBMING CODE 2004
Permit 524409 · COMPLETED
INSTALL 8 DOWNLIGHTS, 5 - 2X4 LIGHTS, 10 DUPLEX RECEPTS, 2 GFI DUPLEX TO ACCOMMODATE NEW LAY OUT UTILIZING EXISTING CIRCUITRY AS PER 2008 NEC (CC DISTRICT)
Permit 22602 · COMPLETED
10/18/2013 ERECT ASSEMBLY TENT (30'X40') MAGERMAN BAR MITZVAH
Permit 22283 · COMPLETED
ERECT ASSEMBLY TENT (20'X30')FOR WHYY PRESIDENTS DINNER
Permit 398418 · COMPLETED
RELOCATION OF POWER TO FEED OFFICE FURNITURE. ADDITION OF 2-2X4 PARABOLIC FIXTURES. REWIRE SWITCHING TO SEPARATE LIGHTING AS PER 2008 NEC
License 559288 · Inactive
ANTI DEFAMATION LEAGUE · Expires 2012-10-31 · Inactive 2012-09-20
Permit 266202 · COMPLETED
INSTALL SIX (6) COMBINATION SPEAKER/STROBES,CEILING MOUNT CONNECTING TO EXISTING LOOP, AS PER NFPA-72 (CC DIST)
Permit 266198 · COMPLETED
INST FA EQUIP W/(1) PWR SUP,PROV 110VAC TO PWR SUP,INST (6)COMB CEILING MOUNT SP/STRS,CEILING MOUNT-INST (3) STR ONLY CEILING MOUNT,(2)ADD RELAYS INTERF W/PWR SUP/ANSUL MON (5)ADD SMK DET'S,(2)ADD HTS,(3)ADD PULL ST,REMOVE ALL EX DEVS,PROV 110VAC PWR TO NEW PWR SUP PER NFPA-72(CC DIST)
Permit 259912 · COMPLETED
RENOVATION OF RESTAURANT (DINING ROOM & KITCHEN), AS PER 2005 NEC (CC DIST)
Permit 256772 · COMPLETED
COMBINATION SPEAKER STROBES, STROBE ONLY INSTALLED IN CONDUIT AND BACKBOXES WHERE NEEDED, FIRE ALARM AS PER NFPA-72 (CC DIST)
Case 60146 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Permit 19912 · COMPLETED
9/30/09-ERECTION OF (1)-30X90 ASSEMBLY USE TENT FOR WHYY TRADE SEMINAR
Permit 230553 · COMPLETED
INSTALL NEW FIRE SUPPRESSION SYSTEM AS PER PLANS
Permit 223279 · COMPLETED
FURNISH/INSTALL 250 NEW LIGHTS, 30 NEW SWITCHES, DIMMING CONTROL, 100 RECEPT'S, 10 FLOOR BOX RECEPTACLES, 2 TRANSFORMERS, 8 NEW PANELS, ADD 2 FIRE ALARM PULL STATIONS, 6 HORN STROBES, 6 STROBES/2 DUCT DETECTORS, AS PER 2005 NEC & NFPA-72 (CC DIST)
Permit 220515 · COMPLETED
HVAC, INCLUDING DUCTWORK AS PER PLAN.
Permit 221488 · COMPLETED
FIXTURE INSTALLATION
Case 60223 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Permit 216094 · COMPLETED
ALTERATIONS TO EXISTING RADIO/TELEVISION BUILDING
Permit 216839 · COMPLETED
CONSTRUCTION OF A TWO STORY ADDITION FOR USE AS PART OF AN EXISTING TELEVISION STUDIO.
Permit 215399 · COMPLETED
SITE WORK ADDING 4 CATCH BASINS
Permit 18905 · COMPLETED
5/11/09 - TENT INSTALLED ON WHYY SITE FOR COCKTAIL PARTY
Permit 198944 · COMPLETED
2 STORY EXPANSION TO THE EXISTING WHYY STATION WITH CONSTRUCTION OF 1 LOADING AND 6 VEHICULAR PARKING SPACES
Permit 76099 · COMPLETED
Permit 61799 · COMPLETED
HISTORICAL REGISTERED PROPERTY. INTERIOR ALTERATIONS TO A PARTIAL TENANT SPACE ON THE 8TH FLOOR. ALL WORK SHALL CONFORM TO THE APPROVED PLANS.
Permit 61818 · COMPLETED
INTERIOR ALTERATIONS AS PER PLANS
Case 60146 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Permit 54516 · COMPLETED
INTERIOR RENOVATIONS PER PLANS
Permit 55510 · COMPLETED
AMEND BUILDING PERMIT A/P 54513 TO CORRECT ADDRESS
Case 60208 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 60208 · CLOSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. City marked the record closed; open the case for the closing reason.
Case 61495 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Case 60140 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 60140 · PASSED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked passed.
Case 60223 · FAILED
Legacy inspection shorthand; confirm the inspection type and scope in the City case file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
What this record suggests
The City file documents 57 permits touching kitchen work, bathroom work, electrical work, plumbing. 54 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Whyy INC · corporate / LLC owner
• Tax bills mail to 170 N Independence W Mall, Philadelphia PA, 19106
170 N Independence Mall W sits on the 100 block of N Independence Mall. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 150 N Independence Mall W · 190 N Independence Mall W
This report was assembled Jul 10, 2026, 5:14 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)