2026 taxable assessment $892,300 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $1,024,600; it is not the 2026 billed-year value.
House report
3 bd · 2 ba · 3 stories · 3,336 sqft · RSA5 · built 1925
Owner-occupied · assessed $992K (2026) · 2027 OPA assessment $1.0M · sold 5×. On the 1200 block of S 10th St.

Open the research chat with this property already in context. Curated questions are free.
“Open” reflects records available then historical records keep their source dates estimates are labeled
BlockReport can explain a discrepancy, but it cannot rewrite an official City record. Use the agency that owns the underlying fact:
Property tax
BlockReport can calculate the annual tax from the City’s taxable assessment. Payments, credits, interest, and a current amount due live separately in Philadelphia Tax Center.
2026 taxable assessment $892,300 × 1.3998%. Estimate—not a bill or account balance.
OPA also publishes a 2027 assessment of $1,024,600; it is not the 2026 billed-year value.
A Tax Center balance is net of bills, payments, credits, interest, and adjustments. A credit—or an amount due—is not automatically “back taxes.”
OPA 0215511002026 OPA removes $100,000 from the taxable assessment through the owner-occupant exemption.
This parcel did not match the June 2022 delinquency snapshot. That absence does not confirm the account is current today.
For a purchase, refinance, or closing, request the City’s official Property Payoff statement in Tax Center under “More options.”
Bought for $800K in 2015. Owner pulled a addition and/or alteration permit in 2025.
View supporting records →The record, translated into moves — what a buyer, the owner, and a landlord would each want to check next under Philadelphia's actual rules.
Federal law requires a lead-paint disclosure at sale for any pre-1978 home. If it will be rented, Philadelphia also requires a lead-safe or lead-free certificate before a rental license can issue.
Single-family rowhouse (the classic Philly row). Converting to a duplex or apartments needs a use variance the zoning board rarely grants — Pennsylvania courts require a physical hardship of the lot itself, and economics alone do not qualify.
Derived from the fetched property records and linked City guidance as of 2026. Assessment treatment is not a substitute for an exemption approval, live balance, title report, license, occupancy certificate, or inspection. Informational only — not legal, tax, or investment advice.
How this house has moved and where it's pointed: every fetched annual City assessment, charted against its block and ZIP; appreciation includes the full-period compound rate and the latest year-over-year change. The 5-year figure simply extends that historical pace. Yield estimates rent-vs-price from area rents. Ask the record to dig into any number.
Assessment vs. the block and ZIP · every dated City record marked on the line
Each icon sits on its recorded date; records without a day are labeled and centered within their year. Select one to explain the filing.
Bought for $800K in 2015. Owner pulled a addition and/or alteration permit in 2025.
Records behind the chart
The chart above is the primary timeline. This drawer preserves every underlying dated row and its filed status for source-level review.
Permit EP-2025-003637 · Completed
Moving devices around in kitchen Add one circuit
Permit PP-2025-005120 · Completed
Installing new water and drains to the kitchen sink
Permit RP-2025-002914 · Completed
For alterations to an Existing One Family Dwelling as per attached standard. Deviations from this standard will result in permit revocation and require submission of construction plans. Separate permits are required for plumbing and electrical work and the installation of heating/cooling appliances. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; INCLUDING UNDERPINNING, EXCAVATION, AND REMOVAL OF FOUNDATION SLAB. NO WORK MAY BE PERFORMED IN THE BASEMENT OR CELLAR.
Permit EP-2020-006803 · Completed
8- 15 Amp AFCI Circuit Includes an arc fault protected branch circuit to power devices, lights, and switches 1- 20 Amp GFCI Circuit Includes and arc fault protected branch circuit to power devices, lights, and switches 16- 15 amp Duplex Includes the Duplex style outlet, wiring, box, and cover 3- 20 amp GFCI Includes the GFCI outlet NEMA 5-15R, wiring, box, and cover plate. 3- Light Switch ( One Location) Includes a toggle switch, wiring, box, and cover plate. 6- Light Fixture (Lite weight) Includes the wiring, an electrical box. 1- Refeed front exterior light. The wiring appears to have been replaced but it is fed with the same knob and tube circuit. Install new arc fault protected circuit and repower the fixture. Required dual ground rod installation - Install 2 ground rods 6 feet apart from each other to provide grounding protection of a 200 amp electrical service entrance. Connect into the main Installation of whole house Square D Complete Home Surge Protective (CHSP) device. 1- 3way Light Switch (Two Location) Includes a 3way toggle switch, wiring, box, and cover plate. 2- Decora 4way Light Switch (Multi-Location) Includes a 4way toggle switch, wiring, box, and cover plate. 5- Decora 3way Light Switch (Two Location) Includes a 3way toggle switch, wiring, box, and cover plate. 1- Basement lighting rewiring of existing fixtures and new Lamp Holder where necessary. 1- Lamp Holder Includes the wiring, electrical box, and the installation of a provided utility lamp holder fixture and lamp. 10 recessed lights 4 inch. 10 LED white flush recessed light trims 1- DIVA Dimmer Switch ( One Location) Includes a Dimmer switch, wiring, box, and cover plate. SIEMENS SUBPANEL CORRECTION: The main feeder neutral is spliced improperly in the main panel and the subpanel itself has the grounding and neutral conductors combined which is unsafe. As per 2014 nec Fish Only
Permit 812815 · COMPLETED
UNCOVER EXISTING FAI-PA1#20172423529-"SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
Permit 822233 · COMPLETED
CURB TRAP AND MAIN DRAIN PA20172423529(SFD) "SELF-CERTIFICATION'S ARE NO LONGER PERMITTED" - "ALL EXCAVATIONS AND PLUMBING TRENCHES IN EXCESS OF 5 FEET IN DEPTH MUST HAVE APPROVED SHORING IN PLACE AT THE TIME OF INSPECTION"
Case 564712 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
2017
Case 564712 · Violation 4168984 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 536614 · PASSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked passed.
Case 564712 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 536614 · CLOSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. City marked the record closed; open the case for the closing reason.
Case 536614 · FAILED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 536614 · Violation 4153396 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 226931 · PASSED
A follow-up before or during enforcement escalation; confirm the case sequence in the City file. The cited inspection visit was marked passed.
2015
Case 226931 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
Case 226931 · CLOSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.
Case 155705 · CLOSED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. City marked the record closed; open the case for the closing reason.
Case 226931 · Violation 1624859 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 155705 · Violation 912525 · COMPLIED
City marked this violation complied with; check the resolution date and live case for what was accepted.
Case 155705 · FAILED
A legacy L&I inspection label. The unit inspected housing for property-maintenance, fire-prevention, and related code compliance; the separate status says how that visit ended. The cited inspection visit was marked failed; later rows may show follow-up or resolution.
What this record suggests
The City file documents 6 permits touching kitchen work, electrical work, plumbing, roof work. 6 carries a completed, issued, or approved status; that documents the filing, not the present quality of the work.
Informational only — not investment advice or a consumer report (FCRA).
The city assessor's field record — the physical spec sheet behind the assessed number.
OPA field-assessment attributes. Condition and grade are the assessor's codes, not an inspection.
What owning 1218 S 10th St takes, at your price and your rate. Taxes start with an annual estimate from the City’s taxable assessment, not a current bill or balance; rent starts at the area median. Assessed value is not an asking price — set the price slider to the real one.
When this house last sold (2017) a 30-year mortgage ran about 3.99% — Freddie Mac's average that year.
Estimates for orientation, not advice. Assumes a 30-year fixed loan, $1,400/yr insurance, 1% of price/yr maintenance; taxes use this parcel's taxable assessment, not a live Tax Center balance.
1218 S 10th St sits on the 1200 block of S 10th St. Open the block report to compare its parcels, ownership and public-record history.
See the whole block →Next door: 1216 S 10th St · 1220 S 10th St
This report was assembled Jul 10, 2026, 3:43 AM ET. Available City datasets are queried from OpenDataPhilly (phl.carto.com) and the cited City ArcGIS feeds; record queries paginate rather than silently taking a first page. For this property: Permits: queried · Violations: queried · Investigations: queried · Appeals: queried · Licenses: queried · Building certifications: queried. “Unavailable” means the source query failed or was not supplied, not “no record.” Reports re-pull on view after seven days and on an overnight rolling schedule; citywide benchmarks recompute weekly. Source dates still govern: the parcel-level tax-delinquency snapshot is June 2022 and the separate detailed tax ledger ends in 2016, so neither establishes today’s balance. The live balance and date-effective payoff must be verified in Tax Center. AI-written passages are grounded in the assembled record and rejected if they state a number the record does not hold.
Official city record ↗ · L&I history ↗ · See the whole block · Download this record (JSON)