{"asOf":"2026-07-10T07:35:45.743Z","block":"3700-3799 N BOUVIER ST","blockUrl":"https://blockreport.homes/block/3700-3799-n-bouvier-st","address":"3765 N BOUVIER ST","parcelNumber":"131234200","source":"https://property.phila.gov/?p=131234200","ownerType":"investor","kind":"house","isHouse":true,"residential":true,"taxExempt":false,"institutional":false,"buildingClass":"ROW 3 STY MASONRY","useLabel":"House","owner":"DELCINA FUTURE LLC","coOwner":null,"marketValue":102600,"livableArea":2304,"yearBuilt":1915,"lastSale":{"price":55000,"date":"2019-05-09T04:00:00Z"},"openViolations":0,"violations":[{"number":"1262093","date":"2008-03-27","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null},{"number":"986587","date":"2008-06-16","title":"PROSEC- STD INFO","status":"COMPLIED","resolutionDate":null},{"number":"986586","date":"2008-06-16","title":"EXT A-CLEAN WEEDS/PLANTS","status":"COMPLIED","resolutionDate":null},{"number":"3439864","date":"2014-05-13","title":"LICENSE-RES MFD","status":"COMPLIED","resolutionDate":null},{"number":"3439863","date":"2014-05-13","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null},{"number":"3499413","date":"2015-03-19","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null},{"number":"3499414","date":"2015-03-19","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null},{"number":"3617435","date":"2015-06-30","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null},{"number":"3617434","date":"2015-06-30","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null},{"number":"3890395","date":"2015-08-13","title":"INT S-CLEAN/MAINT SANI, OWNER","status":null,"resolutionDate":null},{"number":"3890394","date":"2015-08-13","title":"EXT S-WINDOW REPAIR/MAINTAIN","status":null,"resolutionDate":null},{"number":"3890393","date":"2015-08-13","title":"DRAINAGE-PUMP BASEMENT WATER","status":null,"resolutionDate":null},{"number":"3890392","date":"2015-08-13","title":"ANNUAL CERT FIRE ALARM","status":null,"resolutionDate":null},{"number":"3890398","date":"2015-08-13","title":"FIRE EXTING-INSTALL MAX 75FT","status":null,"resolutionDate":null},{"number":"3890391","date":"2015-08-13","title":"CO DETECTOR NEEDED","status":null,"resolutionDate":null},{"number":"3890396","date":"2015-08-13","title":"ELEC-FIXTURE/OUTLET LOOSE-RES","status":null,"resolutionDate":null},{"number":"3890397","date":"2015-08-13","title":"FA-REPAIR SYSTEM","status":null,"resolutionDate":null},{"number":"3890390","date":"2015-08-13","title":"FIRE EXTING-NEEDS INSP/TAG","status":null,"resolutionDate":null},{"number":"4295659","date":"2017-02-14","title":"CO DETECTOR NEEDED","status":"COMPLIED","resolutionDate":null},{"number":"4295657","date":"2017-02-14","title":"INT COMBUSTIBLE WASTE ACCUMUL","status":"COMPLIED","resolutionDate":null},{"number":"4295658","date":"2017-02-14","title":"SD-REQD EXIST GROUP R","status":"COMPLIED","resolutionDate":null},{"number":"4295656","date":"2017-02-14","title":"NON-REGULATED LACKS PERMIT","status":"COMPLIED","resolutionDate":null},{"number":"4272766","date":"2017-04-07","title":"VACANT AND OPEN","status":"COMPLIED","resolutionDate":null},{"number":"4272767","date":"2017-04-07","title":"VACANT STRUCTURE AND LAND","status":"COMPLIED","resolutionDate":null},{"number":"4698823","date":"2018-06-05","title":"VACANT AND OPEN","status":"CLOSEDCASE","resolutionDate":null},{"number":"4698824","date":"2018-06-05","title":"EXTERIOR AREA SANITATION","status":"CLOSEDCASE","resolutionDate":null},{"number":"4915817","date":"2019-01-04","title":"VACANT AND OPEN","status":"COMPLIED","resolutionDate":null},{"number":"4915816","date":"2019-01-04","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":null},{"number":"4977737","date":"2019-01-28","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null},{"number":"VI-2025-007793","date":"2025-02-13","title":"CONCRETE COMPONENTS","status":"COMPLIED","resolutionDate":"2025-06-09"}],"violationCases":[{"number":"153169","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2008-03-28","completedDate":"2009-03-27","violations":[{"number":"1262093","date":"2008-03-27","title":"COULD NOT ENTER","status":"COMPLIED","resolutionDate":null}]},{"number":"165281","type":"STANDARD","priority":"STANDARD","responsibility":"BRU","status":"CLOSED","createdDate":"2008-06-16","completedDate":null,"violations":[{"number":"986587","date":"2008-06-16","title":"PROSEC- STD INFO","status":"COMPLIED","resolutionDate":null},{"number":"986586","date":"2008-06-16","title":"EXT A-CLEAN WEEDS/PLANTS","status":"COMPLIED","resolutionDate":null}]},{"number":"430971","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2014-05-13","completedDate":null,"violations":[{"number":"3439864","date":"2014-05-13","title":"LICENSE-RES MFD","status":"COMPLIED","resolutionDate":null},{"number":"3439863","date":"2014-05-13","title":"ANNUAL CERT FIRE ALARM","status":"COMPLIED","resolutionDate":null}]},{"number":"471862","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-03-19","completedDate":"2015-04-30","violations":[{"number":"3499413","date":"2015-03-19","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null},{"number":"3499414","date":"2015-03-19","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null}]},{"number":"488631","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-06-30","completedDate":"2015-08-14","violations":[{"number":"3617435","date":"2015-06-30","title":"EXT A-CLEAN RUBBISH/GARBAGE","status":"COMPLIED","resolutionDate":null},{"number":"3617434","date":"2015-06-30","title":"LICENSE-RES GENERAL","status":"COMPLIED","resolutionDate":null}]},{"number":"497362","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2015-08-13","completedDate":null,"violations":[{"number":"3890395","date":"2015-08-13","title":"INT S-CLEAN/MAINT SANI, OWNER","status":null,"resolutionDate":null},{"number":"3890394","date":"2015-08-13","title":"EXT S-WINDOW REPAIR/MAINTAIN","status":null,"resolutionDate":null},{"number":"3890393","date":"2015-08-13","title":"DRAINAGE-PUMP BASEMENT WATER","status":null,"resolutionDate":null},{"number":"3890392","date":"2015-08-13","title":"ANNUAL CERT FIRE ALARM","status":null,"resolutionDate":null},{"number":"3890398","date":"2015-08-13","title":"FIRE EXTING-INSTALL MAX 75FT","status":null,"resolutionDate":null},{"number":"3890391","date":"2015-08-13","title":"CO DETECTOR NEEDED","status":null,"resolutionDate":null},{"number":"3890396","date":"2015-08-13","title":"ELEC-FIXTURE/OUTLET LOOSE-RES","status":null,"resolutionDate":null},{"number":"3890397","date":"2015-08-13","title":"FA-REPAIR SYSTEM","status":null,"resolutionDate":null},{"number":"3890390","date":"2015-08-13","title":"FIRE EXTING-NEEDS INSP/TAG","status":null,"resolutionDate":null}]},{"number":"573043","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2017-02-15","completedDate":null,"violations":[{"number":"4295659","date":"2017-02-14","title":"CO DETECTOR NEEDED","status":"COMPLIED","resolutionDate":null},{"number":"4295657","date":"2017-02-14","title":"INT COMBUSTIBLE WASTE ACCUMUL","status":"COMPLIED","resolutionDate":null},{"number":"4295658","date":"2017-02-14","title":"SD-REQD EXIST GROUP R","status":"COMPLIED","resolutionDate":null},{"number":"4295656","date":"2017-02-14","title":"NON-REGULATED LACKS PERMIT","status":"COMPLIED","resolutionDate":null}]},{"number":"578341","type":"STANDARD","priority":"STANDARD","responsibility":"VS","status":"CLOSED","createdDate":"2017-04-10","completedDate":"2017-05-18","violations":[{"number":"4272766","date":"2017-04-07","title":"VACANT AND OPEN","status":"COMPLIED","resolutionDate":null},{"number":"4272767","date":"2017-04-07","title":"VACANT STRUCTURE AND LAND","status":"COMPLIED","resolutionDate":null}]},{"number":"637610","type":"STANDARD","priority":"STANDARD","responsibility":"VS","status":"CLOSED","createdDate":"2018-06-06","completedDate":"2019-03-26","violations":[{"number":"4698823","date":"2018-06-05","title":"VACANT AND OPEN","status":"CLOSEDCASE","resolutionDate":null},{"number":"4698824","date":"2018-06-05","title":"EXTERIOR AREA SANITATION","status":"CLOSEDCASE","resolutionDate":null}]},{"number":"669257","type":"UNSAFE","priority":"UNSAFE","responsibility":"CSU","status":"CLOSED","createdDate":"2019-01-04","completedDate":"2019-05-17","violations":[{"number":"4915817","date":"2019-01-04","title":"VACANT AND OPEN","status":"COMPLIED","resolutionDate":null},{"number":"4915816","date":"2019-01-04","title":"UNSAFE STRUCTURE","status":"COMPLIED","resolutionDate":null}]},{"number":"671884","type":"STANDARD","priority":"STANDARD","responsibility":"HCEU","status":"CLOSED","createdDate":"2019-01-28","completedDate":"2019-05-08","violations":[{"number":"4977737","date":"2019-01-28","title":"VACANT STRUCTURE LICENSE","status":"COMPLIED","resolutionDate":null}]},{"number":"CF-2025-009802","type":"NOTICE OF VIOLATION","priority":"STANDARD","responsibility":"PROPERTY MAINTENANCE INVESTIGATOR","status":"CLOSED","createdDate":"2025-02-13","completedDate":"2025-06-09","violations":[{"number":"VI-2025-007793","date":"2025-02-13","title":"CONCRETE COMPONENTS","status":"COMPLIED","resolutionDate":"2025-06-09"}]}],"violYears":[{"y":2008,"n":3,"worst":null},{"y":2014,"n":2,"worst":null},{"y":2015,"n":13,"worst":null},{"y":2017,"n":6,"worst":null},{"y":2018,"n":2,"worst":null},{"y":2019,"n":3,"worst":"UNSAFE STRUCTURE"},{"y":2025,"n":1,"worst":null}],"investigations":[{"caseNumber":"85517","date":"2006-10-17","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"85517","date":"2007-06-18","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"85517","date":"2007-08-06","type":"BP_BLDG","status":"PASSED"},{"caseNumber":"85517","date":"2008-03-12","type":"BP_BLDG","status":"FAILED"},{"caseNumber":"153169","date":"2008-03-27","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"165281","date":"2008-06-16","type":"BRU INSP","status":"FAILED"},{"caseNumber":"85517","date":"2008-06-24","type":"BP_BLDG","status":"CLOSED"},{"caseNumber":"165281","date":"2008-07-29","type":"BRU INSP","status":"PASSED"},{"caseNumber":"85517","date":"2008-09-17","type":"PRECOURT","status":"PASSED"},{"caseNumber":"153169","date":"2009-03-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"153169","date":"2009-03-25","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"430971","date":"2014-05-13","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"430971","date":"2014-06-30","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"430971","date":"2014-08-07","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"430971","date":"2015-01-06","type":"PRECOURT","status":"FAILED"},{"caseNumber":"430971","date":"2015-01-22","type":"PRECOURT","status":"PASSED"},{"caseNumber":"471862","date":"2015-03-19","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"471862","date":"2015-04-30","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"488631","date":"2015-06-30","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"488631","date":"2015-08-07","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"497362","date":"2015-08-13","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"497362","date":"2015-09-15","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"497362","date":"2016-04-06","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"497362","date":"2017-02-14","type":"PRECOURT","status":"CLOSED"},{"caseNumber":"573043","date":"2017-02-14","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"573043","date":"2017-02-16","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"573043","date":"2017-03-02","type":"CEASE INSP","status":"FAILED"},{"caseNumber":"578341","date":"2017-04-07","type":"VAC INSP","status":"FAILED"},{"caseNumber":"573043","date":"2017-04-25","type":"CEASE INSP","status":"CLOSED"},{"caseNumber":"578341","date":"2017-05-17","type":"VAC INSP","status":"PASSED"},{"caseNumber":"573043","date":"2017-09-14","type":"PRECOURT","status":"PASSED"},{"caseNumber":"637610","date":"2018-06-05","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"637610","date":"2018-07-20","type":"HCEU INSP","status":"CLOSED"},{"caseNumber":"669257","date":"2019-01-04","type":"CSUINITIAL","status":"FAILED"},{"caseNumber":"669257","date":"2019-01-08","type":"CSUINITIAL","status":"CLOSED"},{"caseNumber":"671884","date":"2019-01-28","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"671884","date":"2019-03-14","type":"HCEU INSP","status":"FAILED"},{"caseNumber":"671884","date":"2019-05-07","type":"HCEU INSP","status":"PASSED"},{"caseNumber":"CF-2025-009802","date":"2025-02-13","type":null,"status":"FAILED"},{"caseNumber":"CF-2025-009802","date":"2025-06-09","type":null,"status":"PASSED"}],"inspYears":[{"y":2006,"fails":1,"passes":0},{"y":2007,"fails":1,"passes":1},{"y":2008,"fails":3,"passes":2},{"y":2009,"fails":1,"passes":0},{"y":2014,"fails":2,"passes":0},{"y":2015,"fails":5,"passes":3},{"y":2017,"fails":3,"passes":2},{"y":2018,"fails":1,"passes":0},{"y":2019,"fails":3,"passes":1},{"y":2025,"fails":1,"passes":1}],"taxOwed":0,"taxSnapshot":{"available":true,"asOf":"2022-06","matched":false},"taxDelinquencySnapshotAsOf":"2022-06","taxDelinquencySnapshotAvailable":true,"lat":40.01144259588741,"lng":-75.15624984914514,"geom":{"type":"Polygon","coordinates":[[[-75.156096546,40.01144275],[-75.156105856,40.011401001],[-75.156402885,40.011439516],[-75.156393119,40.011484447],[-75.156096546,40.01144275]]]},"liDistrict":"NORTH","certifications":[],"cityRecordAvailability":{"violations":true,"investigations":true,"appeals":true,"certifications":true,"permits":true,"licenses":true},"zip":"19140","beds":null,"baths":null,"stories":3,"lotArea":1344,"zoning":"RSA5","grade":"C+","basement":null,"heater":null,"centralAir":null,"extCond":"7","intCond":"6","garage":null,"homestead":false,"mail":"2915 BOUCK AVE, BRONX NY, 10469","mailOut":true,"appeals":[],"taxYears":[{"year":2012,"total":269.46,"principal":0,"interest":167.49,"penalty":64.14},{"year":2013,"total":235.02,"principal":0,"interest":135.27,"penalty":66.45},{"year":2014,"total":330.41,"principal":0,"interest":101.82,"penalty":80.97},{"year":2015,"total":1364.3,"principal":1002.85,"interest":110.31,"penalty":74.64}],"taxNet":2199.19,"taxLien":true,"taxLedgerThrough":2016,"taxLedgerAvailable":true,"timesSold":2,"abated":false,"assessmentExemption":false,"exemptionBasisVerified":false,"valueSeries":[{"y":2016,"v":66800,"taxable":66800},{"y":2017,"v":66800,"taxable":66800},{"y":2018,"v":66800,"taxable":66800},{"y":2019,"v":70100,"taxable":70100},{"y":2020,"v":72500,"taxable":72500},{"y":2021,"v":72500,"taxable":72500},{"y":2022,"v":72500,"taxable":72500},{"y":2023,"v":63200,"taxable":63200},{"y":2024,"v":63200,"taxable":63200},{"y":2025,"v":104800,"taxable":104800},{"y":2026,"v":104800,"taxable":104800},{"y":2027,"v":102600,"taxable":102600}],"taxNow":1467,"familyHeld":false,"lastTransferNominal":false,"permits":[{"number":"173637","date":"2008-08-27","work":"Plumbing","type":"PP_PLUMBNG","description":"PLUMBING PERMIT","status":"COMPLETED","completedDate":"2009-06-01","scope":"REPLACEMENT OF 4\" MAIN DRAINAGE WITH PVC PIPE"},{"number":"173639","date":"2008-08-27","work":"Electrical","type":"EP_ELECTRL","description":"ELECTRICAL PERMIT","status":"COMPLETED","completedDate":"2010-12-14","scope":"200 AMP SERVICE AS PER 2005 NEC (NORTH DIST)"},{"number":"173606","date":"2008-08-27","work":"Alteration","type":"BP_ALTER","description":"ALTERATION PERMIT","status":"COMPLETED","completedDate":"2009-03-19","scope":"REDUCE THE SIZE OF THE BASEMENT WINDOWS. INSTALL NEW BASEMENT WINDOWS.REPLACE BASEMENT BILCO DOOR (NO CHANGE TO OPENING SIZE)."},{"number":"980429","date":"2019-05-29","work":"Demolition","type":"BP_DEMO","description":"DEMOLITION PERMIT","status":"COMPLETED","completedDate":"2019-08-19","scope":"EZ INTERIOR DEMOLITION- FOR THE INTERIOR DEMOLITION ON NON-BEARING PARTITION WALL AND CEILINGS AS PER ATTACHED STANDARD. DEVIATIONS FROM THESE STANDARDS REQUIRE SUBMISSION OF CONSTRUCTION AND SITE PLANS. STRUCTURAL ALTERATION OR REPAIR IS EXPRESSLY PROHIBITED UNDER THIS PERMIT. PROHIBITED STRUCTURAL WORK INCLUDES ANY MODIFICATION TO EXTERIOR WALLS, PARTY WALLS, FLOOR/ROOF FRAMING OR FOUNDATIONS; INCLUDING UNDERPINNING, EXCAVATION, AND REMOVAL OF FOUNDATION SLAB. NO WORK MAY BE PEFORMED IN THE BASEMENT OR CELLAR)"},{"number":"ZP-2020-001496","date":"2020-05-15","work":"Change of Use","type":"Zoning","description":"Zoning Permit","status":"Issued","completedDate":null,"scope":"Residential - Household Living - Two-Family"},{"number":"RP-2020-002851","date":"2020-08-12","work":"Addition and/or Alteration","type":"Residential Building","description":"Residential Building Permit","status":"Completed","completedDate":"2021-09-20","scope":"Full interior renovation to an existing 3-story SFD, converting it to a 2-family dwelling. Scope of the renovation includes new bathrooms, kitchens, interior partitions and finishes, as well as structural repairs including new joists, new wood window headers, general masonry repair, and star bolts at the first and second floors."},{"number":"PP-2021-001454","date":"2021-01-28","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Completed","completedDate":"2021-09-20","scope":"2 kitchens sinks, 2 laundry boxes, 4 water closets, 2 water heaters, 2 stack pipes,4 lavatories, 4 tubs"},{"number":"EP-2021-001710","date":"2021-02-27","work":"Addition and/or Alteration","type":"Electrical","description":"Electrical Permit","status":"Completed","completedDate":"2021-09-22","scope":"Install all new wiring second and third floor, arc fault breakers, ground fault receptacles, new switches, receptacles, lighting fixtures grounding shall be install according to NEC exterior lighting will be installed in front and rear of property, 200 amp existing 2 gang meter already exist for 2 unts"},{"number":"PP-2021-018748","date":"2021-10-13","work":"Alterations","type":"Plumbing","description":"Plumbing Permit","status":"Expired","completedDate":"2022-09-27","scope":"REPAIR/REPLACE curb trap"}],"storyTag":"Renovated & sold on","storyDelta":0.51,"timeline":[{"y":2018,"k":"insp","w":"Inspection failed"},{"y":2019,"k":"sale","p":55000},{"y":2019,"k":"permit","w":"Demolition"},{"y":2019,"k":"viol","w":"3 L&I violations incl UNSAFE STRUCTURE"},{"y":2019,"k":"insp","w":"L&I: 3 failed, 1 passed"},{"y":2020,"k":"permit","w":"Change of Use"},{"y":2020,"k":"permit","w":"Addition and/or Alteration"},{"y":2021,"k":"permit","w":"Alterations"},{"y":2021,"k":"permit","w":"Addition and/or Alteration"},{"y":2021,"k":"permit","w":"Alterations"},{"y":2025,"k":"viol","w":"L&I violation"},{"y":2025,"k":"insp","w":"L&I: 1 failed, 1 passed"}],"rented":true,"licenses":[{"number":"407123","type":"Rental","status":"Inactive","businessName":"ABRAHAM ITUAH (AI OSAZE & SONS ENTERPRISE)","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":2,"issuedDate":"2007-04-19","latestIssueDate":"2018-03-29","expirationDate":"2019-02-28","inactiveDate":"2019-04-29"},{"number":"873557","type":"Rental","status":"Active","businessName":"Delcina Future LLC","revenueCode":"3202","rentalCategory":"Residential Dwellings","units":2,"issuedDate":"2021-07-21","latestIssueDate":"2025-07-22","expirationDate":"2026-07-20","inactiveDate":null}],"units":2,"signals":[],"legalChecks":[{"id":"use-occupancy","level":"attention","title":"Zoning approval is not the occupancy file","finding":"The record identifies more than one dwelling/use.","why":"Philadelphia says a zoning approval or Property Sales Certification can identify a use without proving that it was established under the Building Code. A change of use, unit count, exits, or fire rating can require a Building Permit and Certificate of Occupancy.","action":"Verify the lawful use, unit count, associated construction permits, and Certificate of Occupancy with L&I.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-certificate-of-occupancy/"},{"id":"permit-status","level":"attention","title":"A permit row needs file-level verification","finding":"1 permit not marked completed: PP-2021-018748 (Expired). At least one row also carries a completion date, so the City fields conflict.","why":"Issued work is not the same as approved final work. L&I uses final inspections and required certifications to close construction permits; expired, withdrawn, and completed are different City statuses.","action":"Open the permit file and confirm final inspections, holds, and any resulting occupancy certificate.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"},{"id":"violations","level":"attention","title":"An unsafe-building history still deserves the repair file","finding":"The fetched record shows 0 open and 30 historical violations across 12 cases.","why":"The aggregate currently shows zero open violations, so a historical unsafe/imminently-dangerous row is not a current hazard finding. The repair or demolition permit, final inspection, and case closure are the evidence that resolves the former designation.","action":"Review the Make Safe/repair permit, final inspection, and case closure.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections/violation-and-order-types/"},{"id":"rental-license","level":"verify","title":"A rental license does not transfer with the deed","finding":"1 active Rental License record matched.","why":"If dwelling space is rented, the buyer must obtain a new annual Rental License; the seller’s license is not transferable. New applications require proof of ownership and legal occupancy, tax compliance, no open L&I violations, and lead compliance where applicable.","action":"Plan the buyer’s replacement license before settlement.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"managing-agent","level":"verify","title":"Tax mail goes outside Philadelphia; owner residence still needs verification","finding":"OPA mails the property tax record outside Philadelphia (2915 BOUCK AVE, BRONX NY, 10469).","why":"A tax mailing destination does not establish where the owner lives. If a rental owner lives outside Philadelphia, the City requires a managing agent with a Philadelphia mailing address; the owner remains legally responsible.","action":"Verify the buyer’s residence and, if the buyer will live outside Philadelphia, identify the Philadelphia managing agent on the new license application.","url":"https://www.phila.gov/services/permits-violations-licenses/rent-or-sell-property/get-a-rental-license/"},{"id":"lead","level":"verify","title":"Lead compliance is a separate record","finding":"OPA records a 1915 build year; BlockReport does not receive the Health Department’s unit-level lead certificate file.","why":"Philadelphia requires covered pre-March-1978 rentals to be certified lead-safe or lead-free for a new or renewed lease and for a new or renewed Rental License. A certificate is unit-specific; a renovation does not by itself create an exemption.","action":"Request the current lead certificate or City exemption for every dwelling unit.","url":"https://www.phila.gov/documents/lead-and-healthy-homes-resources-for-landlords/"},{"id":"investigations","level":"verify","title":"Failed inspections are dated events—not the current condition","finding":"21 failed, 10 passed, and 9 CLOSED investigation outcomes are in the fetched history; the latest dated visit was PASSED on Jun 9, 2025.","why":"A PASSED or FAILED value applies to that inspection visit. CLOSED is a separate source status; none of the three alone proves the parent permit or violation case closed—or describes today’s condition.","action":"Open the parent case/permit for each material failure and confirm its later disposition.","url":"https://www.phila.gov/departments/department-of-licenses-and-inspections/inspections-by-permit-type/"}],"closingChecks":[{"title":"Property Sales Certification","body":"The seller must obtain Philadelphia’s certificate showing the base zoning, last use in the zoning record, and open violations. The City warns that it does not prove Building Code occupancy or show zoning overlays.","action":"Obtain the fresh certificate and compare it with the CO, permits, and Atlas overlays.","url":"https://www.phila.gov/services/permits-violations-licenses/get-a-certificate/get-a-property-sales-certification/"},{"title":"Date-effective City Property Payoff","body":"The Tax Center Property Payoff covers Real Estate Tax, Commercial Trash, and L&I abatement-work invoices. Philadelphia says it does not include business-tax debts or liens, water and sewer charges, or fines for code violations.","action":"Request the City statement effective through settlement; read every period and invoice.","url":"https://www.phila.gov/guides/philadelphia-tax-center/what-to-do/"},{"title":"Professional title and water-lien searches","body":"OPA ownership, deed summaries, and a zero tax balance are not clear title. Mortgages, judgments, municipal claims, water liens, easements, heirs, and other encumbrances require separate searches.","action":"Use a Pennsylvania lawyer/title company and obtain owner’s title insurance; order the separate water search/payoff.","url":"https://www.phila.gov/2026-04-07-why-title-insurance-is-your-best-friend-when-buying-a-home-in-philadelphia/","secondaryUrl":"https://www.phila.gov/services/water-gas-utilities/pay-or-dispute-a-water-bill/resolve-water-liens-judgments/"},{"title":"Seller-specific tax relief is not the buyer’s bill","body":"LOOP and low-income or senior Real Estate Tax freezes depend on the qualifying owner and continued program eligibility; a buyer cannot assume the seller’s capped or frozen bill continues. A separately verified property abatement often remains with the property for its remaining term, but program-specific new-owner filing, use, and tax-compliance conditions still must be confirmed—not inferred from the reduced assessment alone.","action":"Have Revenue or OPA identify every current benefit, model the buyer’s bill without seller-specific relief, and confirm any verified abatement in writing.","url":"https://www.phila.gov/services/payments-assistance-taxes/payment-plans-and-assistance-programs/income-based-programs-for-residents/apply-for-the-longtime-owner-occupants-program-loop/","secondaryUrl":"https://www.phila.gov/services/payments-assistance-taxes/taxes/property-and-real-estate-taxes/get-real-estate-tax-relief/tax-freeze/"},{"title":"Seller disclosure and independent inspections","body":"For a covered Pennsylvania residential transfer, obtain the statutory seller disclosure. It reports the seller’s knowledge; it is not a warranty, title search, code review, or substitute for inspections. Because OPA dates this building before 1978, separately obtain the required federal/City lead disclosures and any test results.","action":"Have the agreement and disclosure reviewed for this transaction’s coverage and exceptions.","url":"https://www.pa.gov/agencies/dos/department-and-offices/bpoa/boards-commissions/real-estate-commission"}]}